Ballet TX-LR050629SAM ENGINEERING & TESTING, L.P. Serving The Gee-Industry Since 1974 '~ 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910. FAX: (972) 790-0967 DRILLED PIER INSPECTION REPORT REPORT DATE: 6/30/05 , ,-~, DATE: 6/29/05 CLIENT: Head Construction, Inc. TEST METHOD: Visual 3030 LB J, Suite 700 Dallas, TX 75234~ CASING (YES/NO): YES* CASING DEPTH (FT): * PROJECT: Proposed B~ademy of Texas WATER / DRY (FT): * 145~l~S Court ~lSppell,TX PLUMB (YES I NO): YES ATrN: Ken Head SE&T TECHNICIAN: Dominic Gonzales PROJECT NO.: 286TXIK6 REPORT NO. 19 PAGE 1 OF 4 6 36" 30" 24 19 Hard to ve~/hard gray SHALE 9 30" 24" 22 17 16 30" 24" 22 17 19 30" 24" 23 17.6 24 24" 18" 22 17 23 24" 18" 23 17.5 22 24" 18" 24 18 18 30" 30" 24 18 Notes: * (1). The above pier numbers are per the attached sketch. (2). Water seepa~leS were encountered in all piers. Therefore, steel casin~ls with a 24" diameter/ 15'-16' deep, a 30" diameter/19'-20' deep and a 36" diameter/20' deep were used. {3). All above piem were satisfacto~ and in~ance with the on-site foundation plan by . Steve Foose and dated 511810S. ~ ) J Reinforcing steel placed per plans & specification.~J~iless otl ~rwise noted. It has been a pleasure to serve you on this p~t~ :hat this report is satisfactory. Sadik (SAM)AI-Musawe, M.Sc., Ph. D,, P.E. Civil & Environmental Engineer Texas Registration Number: 61893 SAM ENGINEERING & TESTING, L.P. Serving The Goo-industry Since 1974 ,~ 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 o FAX: (972) 790-0967 CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT CLIENT: Head Construction, Inc. 3030 LB J, Suite 700 Dallas, TX 75234 PROJECT: Proposed Ballet Academy of Texas 145 Fitness Court Coppell, TX ATTN: Ken Head 8E&T TECHNICIAN: Dominic Gonzales LOCATION OF PLACEMENT: Piers # 6 & 9 Time Ardved: 8:00 AM Concrete Supplier: Ticket #: Slump (Inches): Concrete Temperature (F): % Air Content: STANDARD 6" X t2" AREA 28.27 SQ. IN. REPORT DATE: 6/30/05 SAMPLE DATE: 6/29/05 PROJECT NO,: 286TXIK5 REPORT NO.: 19 PAGE 2 OF 4 Southern Star Time Left: 3:30 PM 953440 5.75 Truck #: 8845 91 Time Batched: 9:42 AM N/A Time Sampled: 10:15 AM Product Code: Total No. of Test Cylinders Made: 8 9329 Total Cubic Yards Placed: 40 Cement: N/A Added Water: N/A Fly Ash: N/A Weather Conditions: Cloudy & Warm 94 Coarse A~l~lre~late: N/A Water: N/A N/A % Air Content: N/A Air Temperature (FI: Unit Wei~ mt of Fresh Concrete: lA 7 7/6/05 3000~28 1 B 14 7/13/05 3000/28 1 C 28 7/27/05 3000/28 1 D 28 7/27/05 3000/28 Curing ASTM C-31 Test Method Cylinder Made By: Cylinders Tested By: ) ASTM C-143 ASTM C-39 & 231 SE&T Remarks: Very Truly Yours, Sadik (SAM) AI-Musawe, M.Sc., Ph.D., P.E. Civil & Environmental Engineer Texas Registration Number: 61893 This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. the samples tested and does not necessarily represent identical or similar samples. SAM ENGINEERING & TESTING, L.P. Serving The Geo-lndustry Since 1974 '~ 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 · FAX: (972) 790-0967 CLIENT: PROJECT: CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT Head Construction, mc. 3030 LB J, Suite 700 Dallas, TX 75234 Proposed Ballet Academy of Texas 145 Fitness Court Coppell, TX ATTN: Ken Head SE&T TECHNICIAN: Dominic Gonzales LOCATION OF PLACEMENT: Time Arrived: 8:00 AM Pavement- Southeast Entrance West Side Time Left: 3:30 PM Slump (Inches): 5 91 N/A Concrete Temperature (F): % Air Content: 8 Concrete Supplier: Ticket #: Truck #: Time Batched: Time Sampled: Product Code: Total No. of Test Cylinders Made: Total Cubic Yards Placed: STANDARD 6" X 12" AREA 28.27 SQ. IN. REPORT DATE: 6/30/05 SAMPLE DATE: 6/29/05 PROJECT NO.: 286TXIK5 REPORT NO.: 19 PAGE 3 OF 4 Nelson Bros. 154164 207 9:45 AM 10:40 AM PD00/AEA 40 Cement: N/A Added Water: 15 Gallons Fly Ash: N/A Weather Conditions: Cloudy & Warm Coarse A~l~re~ate: N/A Air Temperature (FI: 94 Water: N/A Unit Concrete: N/A % Air Content: N/A 2A 7 7/6/05 2B 14 7/13/05 2C 28 7/27/05 2D 28 7/27/05 Curing ASTM C-31 Test Method Cylinder Made By: Slump ASTM C-143 ASTM C-39 & 231 SE&T Remarks: 3000/28 3000/28 3000/28 3000/28 Cylinders Tested By: Very Truly Yours, Sadik (SAM) AI-Musawe, M.Sc, Ph.D., P.E. Civil & Environmental Engineer Texas Registration Number: 61893 This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This repod only applies to the samples tested and does not necessarily represent identical or similar samples.