Loading...
Coppell Trade-LR050627CONCRETE COMPRESSIVE STRENGTH TEST ~ 'lrerracon Report Number: 94051190.0043 8901 Carpenter Frwy, Ste #100 Service Date: June 16, 2005 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Report Date: June 27, 2005 Attn: Al Sorrels Project: Coppell Trade Center- Bldg C 5055 Keller Springs Rd Ste 300 NWC Sandy Lake/Freeport Pkwy Addison TX 75001 Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: Supplier: Truck No: Mix I.D. No.: 9506 Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result Set Specimen Diameter Area No. ID (inches) (sq. inches) I 1 6.00 28.27 1 2 6.00 28.27 1 3 1 4 Sample Information Sample Time: Date Cast:June 13, 2005 Technician: Contractor Made Weather Conditions: Placement Method: Sample Locations: Placement Location: Spread Footings: B, C, D, E/14, 15 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM Cl 064 ASTM C138 Age at Date Test Tested (days) 06/20/2005 7 06/20/20O5 07/11/2005 07/11 ~2005 Maximum Compressive Load Strength (lbs) (psi) 92,360 3,270 7 94,770 3,350 Average 3,310 28 28 Comments: Not tested for plastic unit weight. Services - Pick up test cylinders cast by others and return them to the laboratory for curing and testing. Technician: Eric G. Jemigan Report Distribution: (1) Copperl Trade Center LP (1) TechniStn~ctures (1) City of Coppell TX (1) City of Coppell TX (1) Merriman Assoc Inc (1) M~Fadden & Mitler (1) Macatee Engineering Inc Reviewed by: ~ Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted heroin are only applicable to the actual samples tested st the location(s) referenced and are not necessarily Indicative of the properties of other apparently similar or identical materials. Page 1 of CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0010 Service Date: May 26, 2005 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: June 27, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: g40511g0 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: 1:29pm Supplier: TXI Truck No: 510 Mix I.D. No.: 9506 Plant: 141 Ticket No: 53080 ~ lnformation Sample Time: 2:50pm Date Cast: May 26, 2005 Technician: Francisco Morillo Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See Placement Location Placement Location: Column Footings, B, C, D, E/23~' B, C, D, E/24 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: 82 Ambient Temperature, o F: 86 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) Result Specification 4.75 4-6 1 1 6.00 28.27 I 2 6.00 28.27 06/23/2005 1 3 6.00 28.27 06/23/2005 1 4 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at D~e Test Tested (day~ 06/0~2005 7 Maximum Compressive Load Strength (lbs) (psi) 88,230 t 3,120 28 110,110 \ 3,890 28 104,040 \ 3,680 Average ~3,790 Hold The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT teat methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of 2 ,CONCRETE COMPRESSIVE STRENGTH TEST ~ 'l erracon Client: Coppell Trade Center LP Comments (cont'd): Project Number:94051190 Report Numbe~. 94051190.0010 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Francisco Modllo Report Distribution: (1) Coppell Trade Center LP (1) TechniStructures (I) City of Coppetl TX (1) City of Coppell TX (1) Merriman Assoc (1) McFadden & Miller (1) Macatee Engineering Inc The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. T~is report is exclusively for the use of the client indicated above and shall nut be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.