Loading...
Coppell Trade-LR050701 CONCRETE COMPRESSIVE STRENGTH TEST · Report Number: 94051190.0052 Service Date: June 23, 2005 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 ll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 01,2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 5:59am Plant: 141 Supplier: TXI Truck No: 58 Mix I.D. No.: 8206 Water Added Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 68603 Sample Information Sample Tim~: 6:42am Date Cast: June 23, 2005 Technician: David B. Hogland Weather Conditions: Clear Accumulative Yards: 50 Placement Method: Direct Discharge Sample Locations: 100' S fram NW comer of Pavement Placement Location: Pavement, W side Result Specification Test Method 6.50 4-6 ASTM Cl 43 6.0 ASTM C231 82 ASTM C1064 79 ASTM C1084 ASTM C138 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 0613012005 7 87,560 3,100 1 2 6.00 28.27 06/30/2005 7 87,820 3,110 Average 3,110 1 3 07/21/2005 28 1 4 07/21/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests ~re performed in general accordance wfth applicable ASTM, AASHTO, or DOT test methods. This raped is exclusively for the use of the client indicated abow and shall not be reproduced except in full without the written consent of our company. Test results transm~ed herein are only applicable to the actual samples tested at the Iocetion(s) referenced and are net necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0052 Service Date: June 23, 2005 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 'lrerracan 8901 Carpenter Frwy, Ste #100 Datlas, Texas 75247 (214) 630-1010 Report Date: July 01,2005 Project: Coppell Trade Center- Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: g40511g0 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 7:03am Plant: 141 Supplier: TXI Truck No: 68 Ticket No: 68680 Mix I.D. No.: 8206 Water Added Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,O F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Sample Information sample Time: 7:36am Date Cast: June 23, 2005 Technician: David B. Hogland Weather Conditions: Clear Accumulative Yards: 110 Placement Method: Direct Discharge Sample Locations: 200' S from NW comer of Pavement Placement Location: See page 1 Result Specification Test Method 5.75 4-6 ASTM C143 6.2 ASTM C231 84 ASTM C1064 82 ASTM C1064 ASTM C138 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 06/30/2005 7 99,770 3,530 2 2 6.00 28.27 06/30/2005 7 87,830 3,110 Average 3,320 2 3 07/21/2005 28 2 4 07/21/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicebl~ ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use of the client indicated above and shall no~ be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the Iocetien(s) referenced and are not necessarily Indicative of the properties of other apparently similar or identical materials. Page 2 of 3 o~,.,~,-~,~..,~.~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0052 Service Date: June 23, 2005 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 'll'erracan 8901 Carpenter F~vy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 01,2005 Project: Coppell Trade Center- Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 8:30am Plant: 141 Supplier: TXI Truck No: 37 Ticket No: 68823 Mix I.D. No.: 8206 WaterAdded Onsite Before Test: 15 Gallons WaterAdded Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 6.25 Air Content, %: 5.4 Concrete Temperature, o F: 84 Ambient Temperature, o F: 83 Plastic Unit Weight, pcf: Laboratory Test Data Sample Information Sample Time: 9:10am Date Cast: June 23, 2005 Technician: David B. Hogland Weather Conditions: Clear Accumulative Yards: 220 Placement Method: Direct Discharge Sample Locations: 275' S from NW corner of Pavement Placement Location: See page 1 Specification Test Method 4-6 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 06/30/2005 7 90,390 3,200 3 2 6.00 28.27 06/30/2005 7 90,260 3,190 Average 3,200 3 3 07/21/2005 28 3 4 07/21/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: David B. Hogland Report Distribution: (1) Coppell Trade Center LP (1) TechnlStructures (1) C~y of Coppell TX (1) C~y of Coppell TX (1) Merriman Assoc Inc (1) McFadden & Miller (I) Macatee Engineering Inc Reviewed by: ~~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are nut neceseadly indicative of the properties of other apparently similar or identical materials. Page 3 of 3