Shadydale 3&4R-CS050607Water and Sewer Connection - Notes Page
136 Shady Dale (north lot) - Lot 4R, Block C
132 Shady Dale (south lot) - Lot 3R, Block C
General Note - We will use the existing water and sewer tap from the
previous residence connection, to be approved by the city with the
applicable construction permits. The sewer connection will be a minimum
of 10 feet down stream (north) of the water connection.
Water - North Lot - Lot 4R, Block C
The water is currently connected to the existing 8" Supply line 100 feet from
the existing north property boundary. See attached "Water Connection"
reference "W 1".
Water - South Lot - Lot 3R, Block C
The water will be connected to the existing 8" Supply line 60 feet from the
existing south property boundary. See attached "Water Connection"
reference "W2".
Sewer - North Lot - Lot 4R, Block C
The Sewer will be connected to the existing 8" Main Sewer Line to be a
minimum of 10 feet down stream (north) of the water connection. This
connection will be made approximately 90 feet from the north existing
property line. See attached "Sewer Connection" reference "S 1".
Sewer - North Lot - Lot 3R, Block C
The Sewer will be connected to the existing 8" Main Sewer Line to be a
minimum of 10 feet down stream (north) of the water connection. This
connection will be made approximately 80 feet from the south existing
property line. See attached "Sewer Connection" reference "S 1".
2A
SPi~'
2
[37 C7
WATER SHEET
WATER LEGEND
8"
WATER LINE'
S GATE VALVE
'~' FIRE HYDRANT
& GATE VALVE
2"BO
' [3LOW OFF VALVE
8" PROPOSED
WATER LINE
~ VAULT
I
-WIDE MAPPING SYSTEM ~/rT,'E~~~~/~ ~ I
, WATER ,/"~//~--~
RINT DATE 7/8/99