Loading...
Coppell Trade-LR050713CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0064 Service Date: July 5, 2005 Client: Coppeil Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 ' rEffacon 8901 Carpenter Frw¥, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 13, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 6:48am Supplier: TXI Track No: 109 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Plant: 141 Ticket No: 75176 0 Gallons 0 Gallons ~formation Sample Time: 7:10am Date Cast: July 5, 2005 Technician: Eric G. Jemigan Weather Conditions: Clear, warm and humid Accumulative Yards: 90 Placement Method: Direct Discharge Sample Locations: 140' N of Grate inlet Placement Location: E side Pavement and Fire Lane Field Test Data Test Result Specification Test Method Slump, inches: 5.75 3-5 Air Content, %: 3.7 3.4 Concrete Temperature,° F: 90 Ambient Temperature, o F: 85 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 07/12/2005 1 2 6.00 28.27 07/12/2005 1 3 08/02/2005 1 4 08/02/2005 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load ~ (days) (lbs) 7 96,530 ~3,410 ~ 7 95,050 ~ Average 3,390 28 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Tl~e tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested st the Icoation(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0064 Service Date: July 5, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 'lrerfacon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 13, 2005 Project: Coppell Trade Center- Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 7:57am Supplier: TXI Track No: 69 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Plant: 141 Ticket No: 75303 0 Gallons 0 Gallons Sample Information sample Time: 8:15am Date Cast: July 5, 2005 Technician: Eric G. Jemigan Weather Conditions: Partly cloudy, warm Accumulative Yards: 190 Placement Method: Direct Discharge Sample Locations: At Grate inlet (east) Placement Location: SE side of Fire Lane and Pavement Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Result Specification Test Method 6.50 3-5 ASTM C143 4.8 3.4 ASTM C231 88 ASTM C1064 86 ASTM Cl 064 ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 07/12/2005 7 85,850 3,040 2 2 6.00 28.27 07/12/2005 7 88,400 3,130 Average 3,099 2 3 08/02/2005 28 2 4 08/02/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samptse tested at the location(s) referenced and are not necessarily Indicative of the properties of other apparently similar or identical Page 2 of 3 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0064 Service Date: July 5, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 'lrerracon 8901 Carpenter Fnvy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 13, 2005 Project: Coppell Trade Center- Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 9:06am Supplier: TXI Truck No: 69 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, O F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Plant: 141 Ticket No: 75398 0 Gallons 0 Gallons Result 7.50 5.2 90 79 Sample Information Sample Time: 10:17am Date Cast:July 5, 2005 Technician: Eric G. Jernigan Weather Conditions: Cloudy, light rain and windy Accumulative Yards: 290 Placement Method: Direct Discharge Sample Locations: 40' N of SE Approach Placement Location: SE Fire Lane and Pavement for Parking Specification 3-5 3.4 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM Cl 38 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 07/12/2005 7 82,500 2,920 3 2 6.00 28.27 07/12/2005 7 80,140 2,830 Average 2,880 3 3 08/02/2005 28 3 4 08/02/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Edc G. Jemigan Report Distribution: (1) Coppell Trade Center LP (1) TechniStruclures (1) City of Coppell TX (1) City of Coppell TX (1) Merriman Assoc Inc (1) McFadden & Miller (1) Macatee Engineering Inc Reviewed by: sRe~ il~o rr tpDr ~j eR~M a 'nEa'~'~ r The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apperently similar or identical materials. Page 3 of 3 o,.~cs~o~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0036 Service Date: June 14, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 r ff con 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 13, 2005 Project: Coppell Trade Center - Bidg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 6:11am Supplier: TXI Truck No: 510 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Plant: 141 Ticket No: 62261 0 Gallons 0 Gallons Result Slump, inches: 5.00 Air Content, %: 4.2 Concrete Temperature,O F: 92 Ambient Temperature, o F: 74 Plastic Unit Weight, pcf: N/A Laboratory Test Data Sample Information Sample Time: 7:00am Date Cast:June 14, 2005 Technician: Russell Jones Weather Conditions: Partly cloudy Accumulative Yards: 40 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Pavement Specification Test Method 3-5 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) I 1 6.00 28.27 06/21/2005 7 121,990 4,310 1 2 6.00 28.27 06/21/2005 7 120,940 4,280 Average 4,300 1 3 6.00 28.27 07/12/2005 28 148,960 5,270 1 4 6.00 28.27 07/12/2005 28 150,470 5,320 Average 5,300 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in genera{ accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in futl without the written consent of our company. Test results transmitted herein are only applicable to the aotual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of 2 D,~.~ CONCRETE COMPRESSIVE STRENGTH TEST · Report Number: 94051190.0036 Service Date: June 14, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 '1 rerracon 8901 Carpenter Frwy, Ste #1 (30 Dallas, Texas 75247 (214) 630-1010 Report Date: July 13, 2005 Project: Coppell Trade Center- Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 9:49am Supplier: TXI Truck No: 110 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Plant: 141 Ticket No: 62604 0 Gallons 0 Gallons Result Slump, inches: 4.50 Air Content, %: 4.0 Concrete Temperature,° F: 96 Ambient Temperature, o F: 90 Plastic Unit Weight, pcf: N/A Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28.27 Sample Information Sample Time: 10:24am Date Cast:June 14, 2005 Technician: Russell Jones Weather Conditions: Partly cloudy Accumulative Yards: 240 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: See page 1 Specification 3-5 Test Method ASTM Cl 43 ASTM C231 ASTM C1064 ASTM C1064 ASTM Cl 38 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) ~ 06/21/2005 7 130,620 /4,620 06/21/2005 7 131,600 Average . 4,640 07/12/2005 28 161,670 ~ 5,720 07/12/2005 28 155,930 Average 5,620 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Russell Jones Report Distribution: (1) Coppell Trade Center LP (1) TechniStruct utes (1) City of Coppetl TX (1) City of Coppell TX (1) McFadden & Miller Reviewed by: (1) Macatee Engineering Inc Robert D. Senior Projec~nager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not bo reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and ara not necessarily indicative of the properties of other apparently similar or identical Page 2 of 2 MATCHLINE: SEE SHT. I I I I I I I I I $ 89'53'16' E 1275,09' HBCI'F-REACON REPORT NO.