Vista Point II-LR050422CONCRETE CYLINDER TEST REPORT
Vista Point II, Phase I
Highway 121 and MacArthur Boulevard
Coppell, Texas
REPORTED TO: Cadence McShane, Corporation
14860 Montfort Drive, Suite 270
Dallas, Texas 75254
ATTN: Mr. Brandon Perdue
CONTRACTOR: Cadence McShane Corporation
REPORT NO. 124
REG PROJECT NO. 11685
SAMPLE DATE: 04-22-05
TECHNICIAN: M. Wood
Location of Sample
Set Number J Location
J Quantity Represented
1
2
3
4
5
Paving: 70'N, 10'E of SE corner of NE bldg. 20/500
Paving: 75'N, 60'E of SE corner of NE bldg. 120/500
Paving: 75'N, 100'E of SE corner of NE bldg. 220/500
Paving: 60'N, 140'E of SE corner of NE bldg. 350~500
Paving: 75'N, 175'E of SE corner of NE bldg. 460/500
Design Information
Source of Concrete I Mix Identification I Specified Strength p.s.i.
Southern Star 9339 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average
No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
1 9396 04-29-05 7 109430 3870
9396 05-20-05 28 130280 4610
9396 05-20-05 28 128100 4530 4570
9396 Hold H
2 9397 04-29-05 7 115810 4100
9397 05-20-05 28 135140 4780
9397 05-20-05 28 132890 4700
9397 Hold H
3 9398 04-29-05 7 99240 3510
9398 05-20-05 28 118100 4180
9398 05-20-05 28 116540 4120
9398 Hold H
4 9399 04-29-05 7 105060 3720
9399 05-20-05 28 125850 4450
9399 05-20-05 28 123920 4390
9399 Hold H
5 9400 04-29-05 7 101630 3600
9400 05-20-05 28 121660 4310
9400 05-20-05 28 123720 4380
9400 Hold H
4740
4150
4420
435O
2424 STUTZ DR · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 o FAX [214] 350 0019
Cylinder Data
Set Cylinder Time of
No. ID Slump Sample
1 9396 6.0 7:20AM
2 9397 5.5 8:15AM
3 9398 6.0 8:55AM
4 9399 5.5 10:15AM
5 9400 5.5 11:25AM
Concrete Air I Ticket
AirTemp. Temp. EntrainmentI Number
68 75 5.5 777392
69 76 5.5 777403
70 78 5.5 777408
72 76 5.5 777420
72 78 5.5 777431
Mail
Distribution: (1) Cadence McShane, Corporation/
Mr. Brandon Perdue
(1) Jackson-Shaw Company/
Mr. Christopher Gardner
(1) City of Coppell/Ms. Beverly Hurtsman
(1) Good Fulton Farrell/Mr. Rick Myers
(1) McHale Engineering/
Mr. Gary McHale
(1) AECC, Inc./Mr. Chad Stephens
Submitted by:
REED ENGINEERING GROUP, LTD.
Original Signed By
Keith Atkins
Manager, C.M.T.
KENInc