Loading...
Vista Point II-LR050301 GEOTECNNICALAND ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Vista Point II, Phase I Highway 121 and MacArthur Boulevard Coppell, Texas REPORTED TO: Cadence McShane, Corporation 14860 Montfort Drive, Suite 270 Dallas, Texas 75254 ATTN: Mr. Brandon Perdue REPORT NO. 82 REG PROJECT NO. 11685 SAMPLE DATE: 03-01-05 TECHNICIAN: C. Johnson CONTRACTOR: Cadence McShane Corporation Location of Sample Set Number I Location I Quantity Represented 1 Panel: #26, Bldg. 3 40/240 2 Panel: #5, Bldg. 3 110/420 3 Panel: #13, Bldg. 3 210/420 4 Panel: #26, Bldg. 2 320/420 5 Paner: #14, Bldg. 2 410/420 Design Information Source of Concrete I Mix Identification Southern Star 9349 Specified Strength p.s.i. 4000 Test Results Set Cylinder Age @ Total Load Compressive Average No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 1 7317 03-08-05 7 97640 3460 7317 03-29-05 28 133930 4740 7317 03-29-05 28 135710 4800 4770 7317 Hold H 2 7318 03-08-05 7 119580 4230 7318 03-29-05 28 145000 5130 7318 03-29-05 28 149830 5300 5220 7318 Hold H 3 7319 03-08-05 7 112930 4000 7319 03-29-05 28 138130 4890 7319 03-29-05 28 140740 4980 4940 7319 Hold H 4 7320 03-08-05 7 129090 4570 7320 03-29-05 28 158880 5620 7320 03-29-05 28 160810 5690 5660 7320 Hold H 5 7321 03-08-05 7 115260 4080 7321 03-29-05 28 167750 5940 7321 03-29-05 28 170840 6050 6000 7321 Hold H 2424 STUTZ DR. * SUITE 400 * DALLAS, TX 75235 * T~L [214] 350 5600 * F^X [214] 3500019 Cylinder Data Set Cylinder Time of Concrete Air Ticket No. D Slump Sample Air Temp. Temp. Entrainment Number 1 7317 6.0 7:20AM 42 54 NA 764185 2 7318 5.5 8:05AM 42 58 NA 764189 3 7319 6.0 9:10AM 44 60 NA 681625 4 7320 5.5 10:25AM 48 60 NA 764213 5 7321 6.0 12:10PM 56 68 NA 764227 Mail Distribution: (1) Cadence McShane, Corporation/ Mr. Brandon Perdue (1) Jackson-Shaw Company/ Mr. Christopher Gardner (1) City of Coppell/Ms. Beverly Hurtsman (1) Good Fulton Farrell/Mr. Rick Myers (1) McHale Engineering/ Mr. Gary McHale (1) AECC, Inc./Mr. Chad Stephens Submitted by: REED ENGINEERING GROUP, LTD. Original Signed By Keith Atkins Manager, C.MT. KEA/Inc