Loading...
Vista Point II-LR050110GEOTECHNICAL AND G R G I I ~ ENVIRONMENTAL CONSULTANTE CONCRETE CYLINDER TEST REPORT Vista Point II, Phase I Highway 121 and MacArthur Boulevard Coppell, Texas REPORTED TO: Cadence McShane, Corporation 14860 Montfort Drive, Suite 270 Dallas, Texas 75254 ATTN: Mr. Brandon Perdue REPORT NO. 41 REG PROJECT NO. 11685 SAMPLE DATE: 01-10-05 TECHNICIAN: F. Thornton, Jr. CONTRACTOR: Cadence McShane Corporation Location of Sample Set Number J Location I Pier: E-3, Bldg. 1 J Quantity Represented 10/10 Desitin Information I Source of Concrete I Mix Identification I Specified Strength p.s.i. Southern Star 9337 3000 Test Results Set Cylinder Age @ Total Load Compressive Average No. ID Date Tested Test lbs. Stren~lth p.s.i. Strength p.s.i. 1 5858 01-17-05 7 103460 3660 5858 01-17-05 7 99960 3540 3600 5858 02-07-05 28 134950 4780 5858 02-07-05 28 135270 4790 4790 5858 Hold H Cylinder Data Set Cylinder Time of Concrete Air Ticket No. D Slump Sample Air Temp. Temp. Entrainment Number 1 5858 4.75 12:10Pm 75 68 NA 751380 Mail Distribution: (1) Cadence McShane, Corporation/ Mr. Brandon Perdue (1) Jackson-Shaw Company/ Mr. Christopher Gardner (1) City of Coppell/Ms. Beverly Hurtsman (1) Good Fulton Farrell/Mr. Rick Myers Submitted by: REED ENGINEERING GROUP, LTD. Original Signed By Keith Atkins Manager, C.MT. KEA/Inc 24245TUTZ DR. · SUITE 400 · DALLAS, TX 75235 * TEL [214] 3505600 · F^X [214] 3500019