Vista Point II-LR041216 GEOTECHNICALAND ~ J~=J O I I p
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Vista Point II, Phase I
Highway 121 and MacArthur Boulevard
Coppell, Texas
REPORTED TO: Cadence McShane, Corporation
14860 Montfort Drive, Suite 270
Dallas, Texas 75254
ATTN: Mr. Brandon Perdue
REPORT NO. 31
REG PROJECT NO. 11685
SAMPLE DATE: 12-16-04
TECHNICIAN: G. Tsougarakis
CONTRACTOR: Cadence McShane Corporation
Location of Sample
Set Number I Location
J Quantity Represented
9/9
I Manhole: STA 0+00, Line A
Desitin Information
Source of Concrete I Mix Identification I Specified Stren~lth p.s.i.
Southern Star 9375 4000
Test Results
~it. Cylinder Age@ Total Load Compressive Average
ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
5296 12-23-04 7 175370 6210
5296 01-13-05 28 197510 6990
5296 01-13-05 28 194450 6880 6940
Cylinder Data
Set Cylinder Time of Concrete Air Ticket
No. I ID Slump Sample Air Temp. Temp. Entrainment Number
1 5296 1.5 2:45PM 57 64 NA 761798
Mail
Distribution: (1) Cadence McShane, Corporation/
Mr. Brandon Perdue
(1) Jackson-Shaw Company/
Mr. Christopher Gardner
(1) City of Coppell/Ms. Beverly Hurtsman
(1) Good Fulton Farrell/Mr. Rick Myers
Submitted by:
REED ENGINEERING GROUP, LTD.
Original Signed By
Keith Atkins
Manager, C.M.T.
KEA/Inc
2424STUTZ DR. · SUITE 400 * DALLAS, IX 75235 * TEL [214] 3505600" FAX [214] 3500019