Coppell Trade-CS050720 21~ ~0 707D 07/20:05 12:01 FAX 214 630 7070 TERRACON CONSULTANTS Fax Transmittal Date: July 20, 2005 To: See below Project: Fax Number: Copp. ell Trade Center - Bid9 C See below From: Company: Fax Number: Subject: Total No. of Pages: Sue Sluiter for Bobby Ray merracon 8901 John W Carpenter Fwy, Suite 100 Dallas, TX 75247 (214) 630-1010 (214) 630-7070 Concrete Compressive Strength Report #94051190.0024 7 Comments: Bennet RatIiff, Coppell Trade Center LP Brian Degravelle, Merriman Assoc., Inc. Keith Leslie, TechniStructures Rick Stull, McFadden & Miller Dayton Macatee, Macatee Engineering, Inc. Lee Stone, City of Coppel[, Building Inspection Dept. Larry Davis. City of Coppe[l, Construction Insp. Dept. 972-241-7955 214-987-2138 214-258-7128 972-401-1399 214-373-6580 972-304-3514 972-304-3570 'lrerracon Delivering Success for Clients and Employees www.terracon.com 07/20.05 _12 :.0_2 . FAX 21,t 630 7070 TERRACON CONSULTANTS _ ~]002/007 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0024 Service Date: June 7, 2005 Client; Coppell Trade Center LP Report Date: lr ff lcon 8901 Carpenter Fro, y, Ste #100 Dallas, Texas 75247 (214) 630-1010 July 07, 2005. Attn: Bennet Ratliff ~ Project: Coppell Trade Center- Bldg C 5055 Keller Springs Rd Ste 300¢~2/ NWC Sandy Lake/Freeport Pkwy Addison TX 75001 J Coppell, TX Project Number: 94051190 Material Information j Sample Information Specified Strength: 4000 psi (~ 28 Days ~ Sample Time: 8:35am Date Cast: June 7, 2005 / Technician: Moa Odom Batch Time: 5:53am Plant: 41 / Weather Conditions: Partly cloudy Supplier: TXI ~. __Accumulative Yards: 30 Truck No: 807 Ticket No: 57463"-'~lPlacement Method: Direct Discharge Mix I.D No.: 8206 /Sampte Locations: 5' - 15' E of Curb Inlet #6 '~tater Added Onsite ~tefore Test: 0 Gallons / Placement Location: Bldg C. W side Fire Lane & Truck Dock, '~.wa~er Added Onsite After Test: 0 Gallons / See attached sketch Field Test Data Test Result Specification Test Method Slump, inches: 5 75 Air Content~ %: 10.2 Concrete Temperature, o F: 87 Ambient Temperature, o F: 78 Plastic Unit Weight, pcf: 136.0 Laboratory Test Data set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 6.00 28.27 6.00 28.27 5 Max ASTM C143 3-6 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Str~ 06/ 4/2005 7 72,840 06/14/2005 7 74,000 '""Z7,620~ Average 07/05/2005 28 101.580 07/05/2005 28 107,730 Average 3,700 Comments: * Does not comply with specified strength. Services - Obtain samples of fresh concrete at the pla~--~"l~cations, strength samples. The tests were performed in gener~l accordance with applicable ASTM, AASHTO, or DOT test methods. This repgrt la exclusively tor the use of the client indicated above and shall not be reproduced ex~ept In full without the written con~ent of our company Test resul~ transmilte~ herei~ a r e only *ppIlcabfe 1o me actual eample~ tested at the kx:ati*n(s) rei~eren~ed and are not necessarily Indicative o[ the properties o[ other apparently similar ~r laentical 07.'20 05 12:02 FAX 214 630 7070 TERRACON CONSULTANTS ~003,'007 CONCRETE COMPRESSIVE STRENGTH TEST .~epoft Number: 94051190.0024 Service Date: June ?, 2005 Client: Coppell Trade Center LP Attn: Bonnet Ratliff 5055 Keller Spring. Rd Ste 300 Addison TX 75001 'll'erracan Dallas, Texas 75247 (214) 630-1010 Repor~ Date; July 07, 2005 Project: Coppel] Trade Center - BIdg C NWC Sandy Lake/Freeport Pkwy Coppell. TX Project Number: 94051190 Material Information Specitied Strength: 4000 psi ~ 28 Days ~Jatch Time: 7:19am Plant: 41 Supplier: TXI Truck No: 71 Mix I.D. No.: 820~ Water Ad(~ed Onsite Before Test: Water Added Onsite After Test: 10 Gallons Ticket No: 57609 0 Gallons Field Test Data Test Result Slump, inches: 5.50 Air Content, %: 8,7 Concrete Temperature,° F: 87 Ambient Temperature, ° F: 852 Plastic Unit Weight, pcf: 136.0 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq, inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6 00 28.27 2 4 6.00 2B,27 Sample Information sample Time: 7:55am Date Cast: June 7, 2005 Technician: Moa Odom Weather Conditions: Cloudy Accumulative Yards: 110 Placement Method: Direct Discharge Sample Locations: ~i0' - 15' S & 30' E of Curb inlet ~,6 Placement Location: See page I Specification 5 Max 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C 1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 06/14/2005 7 94,990 3,360 06/14/2005 7 92,610 3,270 Average 3,320 07/05/2005 28 114,310 ~4,040 I 07t05/2005 28 116,260 L 4~11D I Average 4,080 Comments: Services - Obtain samples of fresh concrete at the placement locations, pedorm required field tests and cast compressive strength samples. The teats w~ra performed in general accordance with applioable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use al the client Indicated above end sha~l not be reproduoed ex.ap! In full without the written consent of our company. Test results transmitted herein are oniy appliCaDle fo the actL~al sampJes tested at the IDeation(s) referenced and are not necessarily ind~ca6ve of the properties of other ap~ai'ently similar or identioa, I 07,'20,'05 12:02 FAX 214 630 7070 TERRA~O~ CONSULTANTS ~004,'007 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0024 ~er~ice Date: June 7, 2005 Client: Coppell Trade Center LP Attn: Banner Re:lift 5055 Keller Springs Rd Ste 300 Addison TX 7500.1 'lrerracon 8901 Carpenter Frw¥, 5re #100 Dallas, Texas 75247 (214) 5'3E)-1010 Repo~t Date: July 07, 2005 Project: Coppell Trade Center - BId~ C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number; 94051190 Material Information ~pecified Strength: 4000 psi ~ 28 Days Batch Time: 9:42am Supplier: TXI Truck No: 837 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 5.3 Concrete Temperature? F: 89 Ambient Temperature, ° F: 87 Plastic Unit Weight, pcf: 143.2 .Laboratorl/ Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) Plant: 41 Ticket No: 57840 0 Gallons 0 Gallons 3 1 6.00 28.27 3 2 6.00 28.27 3 3 6.00 28.27 3 4 6.00 28 27 Sample Information.. Sample Time: 10:28am Tecl3nician: Mca Odom Weather Conditions: Cloudy Accumulative Yards: 220 Placement Method: Direct Discharge Sample Locations: 40' & 60' E of Curb Inlet #9 Placement Location: See page 1 Date Cast: June 7, 2005 Specification 5 Max 3-6 Test Method ASTM C143 ASTM C231 ASTM C1084 ASTM C1064 ASTM Cl 38 Age at Maximum Compressive Date Test Load Strength Tested (days) 0bs) (psi) 06/14/2005 7 84,820 3,000 06/14/2005 7 88,430 3,130 Average . 3,070 07/05/2005 28 126,190 ~ 07/05/2005 28 123,130 Average 4,4t 0 Comments: Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test rnethe~s. This repo~ Is exblusively for the us~ af t~ bllent [r~dica[ed above and shall not be reproduced except in full withou~ the written ~onsent of ~ ~ompany. TeSt results transmitted herein are onty applicable to the ~tua[ samples tee:ed at the location(s) re~'erenced and are not necessarily indicative o! the prope~ie~ Df other apparently sirnilsr or Identi~l materials. Page 3 o~ 4 07,'20.'05 12:02 FAX 214 630 7070 TERRACON CONSULTANTS ~005,'007 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0024 Service Date; June 7, 2005 Client: Coppell Trade Center LP Attn: Bonnet Ratliff 5055 Keller SpdngS Rd Ste 300 Addison TX 75001 'lrerracon (214) ~30-1010 Report Date; July 07, 2005 P¢oject: Coppell Trade Center - E, Idg C NWC Sandy Lake/Freeport Pkwy Coppell, TX ProjeCt Number: 94051190 Material Information. ..Specified Strength: 4000 psi (~ 28 Days Batch Time: 11:55am Plant: 41 Supplier: TXI Truck No: 837 Ticket No: 58031 Mix I.D. No.: 8206 Water Added Onsite Before Test: 15 Gallons Water Added Onsite After Test: 5 Gallons Plaid Test Data Test Result Slump, inches: 4.00 Air Content, %: 43 Concrete Temperature, o F: 92 Ambient Temperature, o F: 92 Plastic Unit Weight, pcf: 144 8 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (iq-inches) 4 1 6.00 28 27 4 2 6 O0 28.27 4 3 6.00 28.27 4 4 6,00 28.27 ~mation Sample Time: 1:00pm Date Cast: June 7, 2005 Technician: Moa Odom Weather Conditions: Cloudy Accumulative Yards: 310 Placement Method: Direct Discharge Sample Locations: 80' E of Curb Inlet #9 Placement Location: See page 1 Specification Test Method 5 Max ASTM C143 3-6 ASTM C231 ASTM C10~4 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs} , (psi) 06/14/2005 7 114,920 4,060 06/14/2005 7 110,760 3,920 Average 3,990 28 138,610 J 4,900 O7/05/2O05 07/05/2005 28 131,970 /_~,670 Average Comments: NOTE: Plant and superintendent were notified of air content test results. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Moa Odom Report Distribution: (1) Copl;e~l TraCe Center LP (1) TechniStructures (1) Merrirnan Assoc Inc ~~ (1) McFadden&Miller Reviewed by: ~ (1) Mscstcc ~nglneeri~g Inc Robe~ D. Ray,~T. senior Project Manager The tests were pe~ormed in general accordance with applicable ASTM, AASHTO, or DOT t~t m~h~S. Th~ repo~ i5 ~cluslvefy for the uae of the 6lient indicated above a~d ~all not be reproduced except in full without the wri~en ~nt of o~r ~ny. T~ results transited harem ere o~ly applicable to the actual sam¢~ tested at the location(s) referenced and are not n~n~ indicative of ~e proposes of ~er apparently st~llar or idenbcal 07.'20.05 12:03 FAX 214 630 7070 TERRACON CONSULTANTS [~006:007 STATISTICAL ANALYSIS OF CONCRETE MIXTURES Report Number: 94051190.0081 Service Date: July 20.2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 lrf, rracon 8901 Carpenter Frwy, Ste #100 Del~as, 3'exas 75247 [214) 630-1010 Report Date: July 20, 2005 Project; Coppel[ Trade Center - BIdg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Specification Requirements: Concrete Class; 8206 PROJECT DATA 4000 psi ~ 28 Days REPORT OF TESTS Date 05/27/2005 05/27/2005 05/27/2005 05/27/2005 06/07/2005 06/07/2005 06/07/2005 06/07/2005 06/09/2005 06/09/2005 06/0912005 06/09/2005 06/14/2005 06/14/2005 06/16/2005 ~ o~uals or exceeds the project specifications. 06/16/2005 06/16/2005 Average of all sets Number Air Concrete Compressive Running Report Of Slump Content Tamp Strength 3 Test Avg Number Set Samples (in.) (%) (F) PSI PSI 94051190.0012 1 2 6 00 5.5 88 4615 94051190.0012 2 2 5.00 5.7 87 4730 94051190.0012 3 2 5.25 4.9 88 5150 4832 94051190.0012 4 2 5.00 5.7 91 5085 4988 94051190,0024 1 2 5.75 10,2 87 3700 4645 94051190.0024 2 2 5.50 8.7 87 4075 4287 94051190.0024 3 2 5.25 5.3 89 4405 4060 94051190.0024 4 2 4.00 4.3 92 4785 4422 94051190.0029 I 2 5.00 4 0 92 5165 4785 94051190.0029 2 2 6.0 4.2 93 5D35 4995 94051190.0029 3 2 6.25 4.6 93 4975 5058 94051190.0029 4 2 4.50 4.0 95 5230 5080 94051190.0036 1 2 5.00 4.2 92 5295 5167 94051190.0036 2 2 4.50 4.0 96 5615 5380 94051190.0041 5012 94051190.0041 4633 94051190,0041 4112 The tests were performed in general accordance with applicable ASTM, AASHTO, o~ DOT test methods This report is exclusively for the use of the client Indicated above sild shall nol be reproduced except in full without the written consent or our eempany. Test results transmitted herel~ are only applicable to the sctu~l samples tested at the location(s) referenced anti are not necessarily indicative of the properties of other apparently similar or identical 12:03 FAX 214 630 7070 TERRACON CONSULTANTS -- ~007'~007 .~TATISTICAL ANALYSIS OF CONCRETE MIXTURES client'. Coppell Trade Center LP 'Jrerracon Project Number:94051190 Report Number: 94051190.0081 Average of 17 sets --'4720 PSI ~ 28 days Standard Deviation -~ 545 PSi Corrected Standard Deviation for 17 results = 615 PSI 4000 + 1,34 * 615 = 4824 PSI 4000 + 2.33 * 615 - 500 = 4933 PSI Required Avecage Strength per ACI 318 (89) $,3.2.1 = 4933 PSI ACl Criteria is NOT satisfied, Technician: Robert D. Ray, SE T Report Distribution: (1) Coppell Trade Cef~ler LP (1) TechniStructures (1) Merrlman Assoc [nc (1) McFadden & Miller (1) Macatee Engineering Inc Reviewed by: Robc~D. Ray, Senior project M~ll~ger The tests were performed in general accordance Wfih alpgl[ca~[e ASTM, AASHTO, or DOT te~ methods. Thi~ repol~ [$ exclusively far the use of the clier~t indicated above end sheli not be reproduced exCel~t in [uli without [he wriEen conserlt or our ~onlpan¥ Test results transmitted herein are only aPPlicable to the actual ~amples tested at the location(s} referenced end are net nece~t, arlly indicative or the properties of other apparently similar or Identigal