MA FY 0405-LR050603Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPORT OF IN-PLACE DENSITY TEST,~
CLIENT: Pavement Services Corp.
DATE: 3 June 2005
PROJECT: City of Coppell Street Repair Project
Job #03-007, Coppell, TX
JOB NO.: 02.1077
MATERIAL DESCRIPTION: 1) Flex Base - Crushed Concrete and Asphalt
ASTM D 698 STANDARD PROCTOR: 1) 109.0 pcf @ 14.0% Moisture
242)
243)
LOCATION PROCTOR LIFT
Paving Replacement @ S, Village Pkwy.
@ MacArthur Blvd.
approx. 5' W of E end 1 Flex Base
approx. 20' W of E end 1 Flex Base
MOISTURE DRY PERCENT REQUIRED
CONTENT DENSITY COMPACTION COMPACTION
% PCF % %
12.6 105,9 97,1
13,4 110,8 101.6
95+
TECHNICIAN:
DISTRIBUTION:
CDJ
(1) Pavement Services Corp.
(1) City of Coppell
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351~6419 Fax (214) 351-5148