Loading...
SS9901-LR050615Client: Project: GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON 11050 Able$ Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 Concrete Compression Test Report City of Coppell Report Distribution: (1) City of Coppell DeForest Rd. Lift Station Imp, (1) Invoice Copy Force Main Line "D" TMI Report No.: 74792-019 Report Date: 06/15/2005 Specifications Test Data Strength 3600 psi @ 28 Days Placement Date 05/16/2005 Stump 3 in min 5 in max Sampled By Chikezie Kalu Air Content 3 % min 6 % max Weather Clear Concrete Temperature n/a Supplier/Mix Custom Crete/CC1050A Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: 324516 Time Batched: n/a Slump: 4 in Air Content: 5.0 % Concrete Temperature: 78" F Ambient Temperature: 81 ° F Placement Location: Pipe anchor at force main D Time Sampled: 2:20 pm Unit Weight: n/a Yardage (c.y.): n/a Sample Location: Station 0+30 Age Max Load Area Strength Fracture Set # Cylinder Test Date (days) (lbs. force) (sq.in.) (ps~ Type 1 05160501 05/23/2005 7 86310 28.27 3050 unbonded cap 1 05160502 06/13/2005 28 134160 28.27 4740 unbonded cap 1 05160503 06/13/2005 28 127820 28.27 4520 unbonded cap I 05160504 Hold 28 day average 4630 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TERRA-MAR, INC. The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is stdctly prohibited without the express wdtten consent of TMI.