Loading...
SS9901-LR050104CItant: Pro~ect: GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Abtes Ln., Dallas, Texae 75229 phone: (972) 488-8800 fax:(972) 488-8080 Concrete Compression Test Report Cityof Coppell Report Distribution: (1)CftyofCoppell DeForest Rd. Lift Station Imp. Force Main Line "D" TMI Report No.: 74792-011 Report Date: 01/04/2005 Specifications Test Data Strength 4200 psi @ 28 Days Placement Date Slump 3 in min 5 in max Sampled By Air Content 3 % min 6 % max Weather Concrete Temperature n/a Supplier/Mix Ambient Temperature n/a Air Content Method 12/22/2004 Mohammed A. Kashem Cloudy Custom Crete/CCl060A ASTM C-231-B Ticket Number: Slump: Concrete Temperature; Placement Location: Sample Location: 317412 Time Batched: 8:40 am 4.5 in Air Content: 3.1% 46° F Ambient Temperature: 36° F Manhole at 30" main force line D at Station 48+00 Manhole at 30" main fome line D at Station 48+00 Time Sampled: 8:55 am Unit Weight: n/a Yardage (c.y.): 10 of 10 .~ge Max Load Area Strength Fracture Set # Cyl~der Test Date (days) (lbs. force) (sq.ln.) (ps~ Type 1 12220401 12/29/2004 7 110370 28.27 3900 unbonded cap 1 12220402 01/19/2005 28 178820 28.27 6320 unbonded cap 1 12220403 01/19/2005 28 182470 28.27 6450 unbonded cap 1 12220404 Hold 28 day average 6390 Normal cylinder size: ~"x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, O172, C1064, and C617 or C1231, TERRA-MAR, INC. The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is stdctly prohibited without the express written consent of TMI.