Concrete Compression Test Report
City of Copperl Report Distribution: (1) City of Coppell
DeForest Rd. Lift Station Imp.
Force Main Line "D"
TMI Report No,: 74792-009
Repor~ Date: 12/29/2004
Specifications Test Data
Strength 4200 psi @ 28 Days Pracement Date 12/20/2004
Slump 3 in min 5 in max Sampled By Lee Lewis
Air Content 3 % min 6 % max Weather Clear
Concrete Temperature n/a Supplier/Mix Custom Crete/CC1060B
Ambient Temperature n/a Air Content Method
Ticket Number: 317673 Time Batched: 9:15 Time Sampled: 9:15
Slump: 2.5 in* Air Content: n/a Unit Weight: n/a
Concrete Temperature: 62° F Ambient Temperature: 46° F Yardage (c.y.): 7 of 7
Placement Location: Line D
Sample Location:
Manhole foundation at Station 40+00
An asterisk ( ) appears next to field data which does NOT meet specifications,
Age Max Load Area Strength
Set # Cyl#der Test Date (days) (lbs. force) (sq.in.) (psl~
Fracture
Type
1 12200401 12/27/2004 7 126410 28.27 4470
1 12200402 01/17/2005 28
1 12200403 01/17/2005 28
1 12200404 Hold
Normal cylinder size: 6" x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231.
unbonded cap
TERRA-MAR, INC.
Mike Fuller
Project Manager
The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of