Ballet TX-LR050728S^M E.G ,EE. ,G & TESTING, ,.P.
Serving The Geo-lndustry Since 1974 '~
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 · FAX: (972) 790-0967
CLIENT:
=ROJECT:
Head Construction, Inc.
3030 LBJ, Suite 700
Dallas, TX 75234
CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT
STANDARD 6" X '12"
AREA 28.27 SQ. IN.
Proposed Ballet Academy ~~''''''/
lc4o~ F il~tl~eST)~ Court ~'-
~,'l-rN: Ken Head
SE&T TECHNICIAN: Dominic Gonzales
LOCATION OF PLACEMENT: Piers # 6 & 9
Time Arrived: 8:00 AM
Time Left: 3.'30 PM
Slump (Inchesl:
Con~.,~ Temperature (FI: 91
% Air Content:
Total No. of Test Cylinders Made: 8
Total Cubic Yards Placed: 40
Added Water: N/A
5.75
N/A
Cloudy & Warm
94
N/A
Weather Co.,~;[;o.s:
Air Temperature (F):
REPORT DATE: 7/28105
SAMPLE DATE: 6/29/05
PROJECT NO.: 286TXIK$
REPORT NO.: 19
PAGE 2 OF 4
Concrete Supplier, _ So.u~e~,j._Ster
Ticket #: 953440
Truck #: 8845
Time Batched: 9:42 AM
Time Sampled: 10:15 AM
Product Code: 9329
Cement: N/A
Fly Ash: N/A
Coarse Aggregate: N/A
Water. N/A
Air Content: N/A
1A 7 7/6/05 147 59,000 2086 Shear 3000~28
1 B 14 7/13~05 146 73,000 3000/28
1C 28 7/27/05 146 85,000 3006 le Shear 3000/28
1D 28 7/27/05 146 ~,000 le Shear 3000/28
Curing ASTM C-31 Test Method Cylinders Tested By:
~ ASTM C-143 ASTM C-39 & 231 SE&t
Remarks: Te~e~ conc~e n~ee~/exceede required strength.
Very Truly Yours,
Sadik (SAM) AI-Musawe, MSc., Ph.D., P.E.
Civil & Environmental Engineer
Texas Registration Number: 61893
This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent.
and does not necessarily represent identical or similar samples.
G:/20051286txik51CpistrlCpistr19SF
SAM ENGINEERING & TESTING, L.P,
Serving The Goo-Industry Since 1974 '~
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 · FAX: (972) 790-0967
CLIENT:
3ROJECT:
Head Construction, Inc.
3030 LB J, Suite 700
Dallas, TX 75234
CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT
STANDARD 6" X 12"
AREA 28.27 SQ. IN.
Proposed Ballet Academy of Texas
145 Fitness Court
Coppell, TX
A'FI'N: Ken Head
SE&T TECHNICIAN: Dominic Gonzales
LOCATION OF PLACEMENT: Pavement - Southeast Entrance, West Side
REI~ORT DATE: 7/28/05
SAMPLE DATE: 6/29/05
PROJECT NO.: 286TXlK5
REPORT NO.: 19
PAGE 3 OF 4
Concrete Supplier: Nelson Bros.
Ticket #: 154164
Truck #: 207
Time Batched: 9:45 AM
Time Arrived: . 8:00 AM . _
Time Left: 3:30 PM
Slump (Inches): 5
Concrete Temperature (FI: 91
% Air Content: N/A
Total No. of Test C~/li~Gers Made: 8
Total Cubic Yards P{ace~: 40
Added Wa~er: 15 Gallons
, Weather Conditions: Cloud), & Warm
Air Tempera[urn (F): 94
Unit N/A
Time Sampled: 10:40 AM
Product Code: PD00/AEA
Cement: N/A
FI}/Ash: N/A
Coarse Aggregate: N/A
Water: N/A
% Air Content: N/A
2A 7 7/6/05 148 63,000
2B 14 7/13/05 142 81,000
2C 28 7/27/05 142 92,000
2D 28 7/27/05 143 91,000
Curing ASTM C-31 Test Method
Slump ASTM C-143 ASTM C-39 & 231
Remarks: Tested concrete meets/exceeds required strength.
2864
3253
3218
CylinderMade By:
SE&T
le Shear 3000/28
3000128
le Shear 3000/28
le Shear 3000/28
Cylinders Tested By:
SE&T
Very Truly Yours,
Sadik (SAM)AI-Musawe, MSc., Ph.D., P.E.
Civil & Environmental Engineer
Texas Registration Number: 61893
This report is for the sole use of the client addressed. The use of our company name must receive our prior wriffen consent.
This report only applies to the samples tested and does not necessarily represent identical or similar samples.
G:/2005/286txikS/CpistrlCpistr 19SF