Rozas Addn-LR050726CMJ ENGINEERING, INC. Concrete Compression Test Report 7636 Pebbre Drive Fort Worth, Texas 76118 Client: Tri-Star Construction Project: Dr. Roza's Office Coppell CMJ Report No.: 548-5051-013 Report Date: 07/26/2005 Tel: (817) 284-9400 Fax: (817) 589-9993 Report Distribution: (1) Tri-Star Construcfion (1) City of Coppell Specifications Test Data Strength 3600 psi @ 28 Days Placement Date 06/13/2005 Slump 3 in min 5 in max Sampled By John Reid Air Content n/a Weather Ovemast/Light Wind Concrete Temperature n/a Supplier/Mix Redi-Mix/9265 Ambient Temperature n/a Air Content Method ASTM C231 Ticket Number: Slump: Concrete Temperature: Placement Location: 148502 Time Batched: 09:35 Time Sampled: 10:55 2 in* Air Content: 2.6 % Unit Weight: n/a 89° F Ambient Temperature: 90° F Yardage (c.y.): 5 of 5 Manhole at West Side of Job Site Sample Location: Same An asterisk (*) appeam next to field data which does NOT meet specifications. Concrete Compression Test Results ,~,ge Max Load Area Set # CyI~t der Test Date (days) (lbs. force) (sq.in.) St~th Fracture Type 01 DRO06130501 06/20/2005 7 123620 28.27 4370 01 DRO06130502 07/11/2005 28 150180 28.27 5310 01 DRO06130503 07/11/2005 28 145540 28.27 5150 01 DRO06130504 Hold 28 day average 5230 Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. 15 Gallons of Water Added On-Site by the Contractor CMJ Engineering, Inc R. Carl Lee, S.E.T. CMT Manager LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, Items or areas regardless of similarity. Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. Page l of 1