Loading...
Rozas Addn-LR0507257636 Pebble Ddve For~ Worth, Texas 76118 Client: Tri-Star ( Coppell ~ CMJ Report No.: 548-5051-012 Report Date: 07/25/2005 INC. Concrete Compression Test Report 1817)284-9400 Fax: (817) 589-9993 ~ Report Distribution: (1) Tri-Star Construcflon (1) City of Copperl Specifications Test Data Strength 3600 psi @ 28 Days Placement Date 06/09/2005 Slump 3 in min 5 in max Sampled By John Reid Air Content n/a Weather Clear/Light Wind Concrete Temperature n/a Supplier/Mix Redi-Mix/115 Ambient Temperature n/a Air Content Method ASTM C231 Ticket Number: 148319 Time Batched: 12:15 Time Sampled: 13:15 Slump: 2.25 in* Air Content: 2.6 % Unit Weight: n/a Concrete Temperature: 85° F Ambient Temperature: 92° F Yardage (c.y.): 10 of 10 Placement Location: Manhole at NE Entrance Sample Location: Same An asterisk (*) appears next to field date which does NOT meet specifications. Concrete Compression Test Results ~,ge Max Load Area Streneth Set # Cylinder Test Date (days) (lbs. force) (sq.in.) (ps~ 01 DRO06090501 06/16/2005 7 124120 28.27 4390 01 DRO06090502 07/07/2005 28 152340 28.27 5390 01 DRO06090503 07/07/2005 28 155940 28.27 5510 01 DRO06090504 Hold 28 day average 5450 Normal cylinder size: 6"x 12" Field and laboratory tests by CMJ are per applicable ASTM Stendards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. Type Gallons of Water Added On-Site CMJ Engineering, Inc ~,/ R. Carl'Lee, S.E.T. CMT Manager LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our repods are produced solery for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, inc. Ol Page 1 ofl