Loading...
Coppell Trade-LR050729CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0061 Service Date: June 30, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Spdngs Rd Ste 300 Addison TX 75001 'l erracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 29, 2005 Project: Coppell Trade Center- Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 6:54am Supplier: TXI Truck No: 111 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Plant: 141 Ticket No: 73152 0 Gallons 0 Gallons Result Slump, inches: 4.50 Air Content, %: 6.2 Concrete Temperature, o F: 90 Ambient Temperature, o F: 83 Plastic Unit Weight, pcf: 144.3 Laboratory Test Data Sample Information sample Time: 8:10am Technician: Kudret Aksu Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Paving Specification Test Method 3-5 ASTM C143 3-6 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Date Cast:June 30, 2005 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 07/07/2005 1 2 6.00 28.27 07/07/2005 1 3 6.00 28.27 07/28~2005 1 4 6.00 28.27 07/28/2005 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 85,360 3,020 7 87,010 3,080 Average 3,050 28 116,280 4,110 28 113,000 4,000 Average 4,060 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) raferancad and ara not necessarily indicative of the pmpe~ies of other apperantly similar or identical materials, Page 1 of 3 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0061 Service Date: June 30, 2005 'lrerracon 8901 Carpenter Frwy, Sts #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Spdngs Rd Ste 300 Addison TX 75001 Report Date: July 29, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 7:57am Plant: 141 Supplier: TXI Truck No: 70 Ticket No: 73265 Mix I.D. No.: 8206 Water Added Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 4.75 Air Content, %: 6.1 Concrete Temperature,° F: 91 Ambient Temperature, o F: 87 Plastic Unit Weight, pcf: Laboratory Test Data Sample Information sample Time: 9:00am Technician: Kudret Aksu Weather Conditions: Clear Accumulative Yards: 60 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Paving Specification Test Method 3-5 3-6 Date Cast: June 30, 2005 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 2 1 6.00 28.27 07/07/2005 2 2 6.00 28.27 07/07/2005 2 3 6.00 28.27 07/28/2005 2 4 6.00 28.27 07/28/2005 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 98,970 3,500 7 97,640 3,450 Average 3,480 28 118,260 4,180 28 120,130 4,250 Average 4,220 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full withoat the written consent of our company. Test results transmitted herein are only applicable to the actual sampres tested at the location(s) referenced and are not necessarily indicative of the properties of ether apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0061 Service Date: June 30, 2005 lrefracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: July 29, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 10:19am Supplier: TXI Truck No: 507 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Plant: 141 Ticket No: 73510 0 Gallons 0 Gallons Result 4.50 6.1 93 98 Sample Information Sample Time: 11:05am Technician: Kudret Aksu Weather Conditions: Clear Accumulative Yards: 150 Placement Method: Direct Discharge Sample Locations: See attached sketech Placement Location: Paving Specification Test Method 3-5 3-6 Date Cast: June 30, 2005 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 3 1 6.00 28.27 07/07/2005 3 2 6.00 28.27 07/07/2005 3 3 6.00 28.27 07/28~2005 3 4 6.00 28.27 07/28/2005 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 111,200 3,930 7 110,030 3,890 Average 3,910 28 129,340 4,570 28 128,260 4,540 Average 4,560 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Kudret Aksu Report Distribution: (1) Coppell Trade Center LP (1) Merfiman Assoc Inc . (t) TechniStructures (1) McFadden & Miller Reviewed by: (1) City of Coppell TX (1) Macatee Engineering Inc ' Robert D. Ray, S~. (1) city of Coppe, TX Senior Project.~ager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusivery for the §se of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein ara only app[icabre to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3 o~.~.~D,~.~o~