Coppell Trade-LR050726CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0080 Service Date: July 18, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 'lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 26, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: 12:47pm Plant: 141 Supplier: TXI Truck No: 803 Ticket No: 83549 Mix I.D. No.: 9506 Water Added Onsite Before Test: 15 Gallons Field Test Data Test Sample Information Sample Time: 1:30pm Date Cast: July 18, 2005 Technician: CharlesA. Patterson Weather Conditions: Mostly sunny Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Footings A.3/2 Placement Location: Retaining Wall Beam W of building & footings Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Result Specification Test Method 4.75 3-5 ASTM C143 3.3 3-7 ASTM C231 94 ASTM Cl 064 90 ASTM C1064 ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 07/25/2005 7 94,510 1 2 08/15/2005 28 1 3 08/15/2005 28 1 4 09/12/2005 56 3,340 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. . CONCRETE COMPRESSIVE STRENGTH TEST Client: Coppell Trade Center LP Project Number:94051190 Report Number: 94051190.0080 Comments (cont'd): Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, pen~orm required field tests and cast compressive strength samples. Technician: Chades A. Patterson Report Distribution: (1) Coppell Trade Center LP (1) Merriman Assoc Inc (1) TechniStructures (1) McFadden & Miller Reviewed by: The tests were ,performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the ~ocation(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2