Coppell Trade-LR050725CONCRETE COMPRESSIVE STRENGTH TEST 'Report Number: 94051190.0052 Service Date: June 23, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 'lreffacDn 8901 Carpenter Frwy, Ste #100 Dalles, Texas 75247 (214) 630-1010 Report Date: July 25, 2005 Project: Coppell Trade Center- Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 5:59am Plant: 141 Supplier: TXI Truck No: 58 Ticket No: 68603 Mix I.D. No.: 8206 WaterAdded Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 6.50 6.0 82 79 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Sample Information Sample Time: 6:42am Date Cast: June 23, 2005 Technician: David B. Hogland Weather Conditions: Clear Accumulative Yards: 50 Placement Method: Direct Discharge Sample Locations: 100' S from NW corner of Pavement Placement Location: Pavement, W side Specification Test Method 4-6 ASTM C143 ASTM C231 ASTM Cl 064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 06/30/2005 7 87,560 3,100 06/30/2005 7 87,820 3,110 Average 3,110 07/21/2005 28 113,340 4,010 07/21/2005 28 117,210 4,140 Average 4,080 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is excJusiveiy for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only appricable to the actual samples tested at the Iocetion(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0052 Service Date: June 23, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 rErracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 25, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 7:03am Plant: 141 Supplier: TXI Truck No: 68 Mix I.D. No.: 8206 WaterAdded Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, O F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.75 6.2 84 82 Ticket No: 68680 Sample Information Sample Time: 7:36am Date Cast: June 23, 2005 Technician: David B. Hogland Weather Conditions: Clear Accumulative Yards: 110 Placement Method: Direct Discharge Sample Locations: 200' S from NW comer of Pavement Placement Location: See page 1 Specification 4-6 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 2 1 6.00 28.27 06130/2005 2 2 6.00 28.27 06/30/2005 2 3 6.00 28.27 07/21/2005 2 4 6.00 28.27 07/21/2005 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 99,770 3,530 7 87,830 3,110 Average '3,320 28 117,590 4,160 28 113,980 4,030 Average 4,100 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not bo reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propeRies of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0052 Service Date: June 23, 2005 lreffr3con 8901 Carpenter Fnvy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Spdngs Rd Ste 300 Addison TX 75001 Report Date: July 25, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 8:30am Plant: 141 Supplier: TXI Truck No: 37 Mix I.D. No.: 8206 Water Added Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 6.25 Air Content, %: 5.4 Concrete Temperature, o F: 84 Ambient Temperature, o F: 83 Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 68823 Sample Information Sample Time: 9:10am Date Cast: June 23, 2005 Technician: David B. Hogland Weather Conditions: Clear Accumulative Yards: 220 Placement Method: Direct Discharge Sample Locations: 275' S from NW corner of Pavement Placement Location: See page 1 Specification Test Method 4-6 Set Specimen Diameter Area Date No. ID (inches) (.sq. inches) Tested 3 1 6.00 28.27 06/30/2005 3 2 6.00 28.27 06/30/2005 3 3 6.00 28.27 07/21/2005 3 4 6.00 28.27 07/21/2005 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM Cl 38 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 90,390 3,200 7 90,260 3,190 Average 3,200 28 113,450 4,010 28 112,740 3,990~ Average 4,000 Comments: * Does not comply with specified strength, Not tested for plastic unit weight. Services- Obtain samples of fresh concrete at the placement locations, pertorm required field tests and cast compressive strength samples. Technician: David B. Hogland Report Distribution: ~ / (1) Coppell Trade C®nler LP (1) Merriman Assoc Inc J~ ~ (1) TechniStructures (1) McFadden & Miller Reviewed by: ~ ~ //'-Tud/'_~/ (1) City of Coppe[I TX (1) Macatee Engineering Inc f ..... ' _-_ _// (1) City of Coppell TX I~oDer~ ~J. Nay, Senior Project The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the cli- -- 'ent indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3