Loading...
ST9703-LR050802 one Engineering 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150. Houston. TX 77040 Corporate Phone: (214) 630-9745 IN-PLACE DENSITY TESTING Client: Project: City of Coppell Ms. Suzan Taylor PO Box 9478 Coppell TX 75019 MacArthur Boulevard WidenLng ST 97-03 Report No.: 238533 Project No.: 0510377 Date of Service: 07/28/2005 Report Date: 08/02/2005 Services: Perform In-Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: JP, J Paving Test Methods: ASTM D-2922 ASTM D-3017 Gauge: Troxler 3430 Gauge Serial No: 35560 Test Mode: DT Moisture Current: 732 Previous: 731 Standard Counts Density Current: 2694 Previous: 2674 M/D No. Description MOISTURE DENSITY RELATIONS Maximum Moisture % Density pcf Tan Sandy Clay w/limestone fragments Project Requirements Moisture Density 20.5 100.5 Optimum +4 95 min FIELD DENSITY TESTS TEST PROBE NO TEST LOCATION DEPTH M/D MOISTURE WET DENSITY DRY DENSITY DENSITY No. (%) (pcl) (pet') (% max) Paving subgrade 6" 100 1 Retest #1 from Report #238300 I 20.6 121.6 100.8 Paving subgrade 6" 98 2 Retest #2 from Report #238300 1 20.6 119.0 98.7 Paving subgrade 6" 98 3 Retest #3 from Report #238300 1 20.6 118.7 98.4 Paving subgrade 6" 97 4 Retest #4 from Report #238300 1 21.3 118.4 97.6 Paving subgrade 6" 98 5 Retest #5 from Report #238300 1 23.0 121.4 98.7 Paving subgrade 6" 100 6 Retest #6 from Report #238300 1 21.6 122.0 100.3 Test results on this report meet project specification. Technician: Joe Jemigan Started: 2:45pm Finished: 4:45pm R°"T~ Report Distribution: ( 1 ) City of Coppell '~ lay Stark (1) City of Coppell Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing We assume no responsibility for variation in quality (composition, appearance, etc.) or any other lecture of similar subject mat~er provided by persons or conditions over which we have no control. Our letters and reportz are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. Page 1 of 1 07TM Rone Engineering Client: Project: 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 REPORT OF CYLINDER COLLECTION City of Coppell Ms. Suzan Taylor PO Box 9478 Coppell TX 75019 MacArthur Boulevard Widening ST 97-03 Report No.: 238653 Project No.: 0510377 Date of Service: 07/30/2005 Report Date: 08/02/2005 Services: Cylinder Collection Report of Collection On this date, a Rone Engineering Services, Ltd. representative(s) arrived on site as scheduled to pick up compressive strength test specimen cast prior to this date. Technician time: Technician: Pat Parks Report Distribution: (1) City of Coppall (1) City of Coppell 7:15am - 8:30am Rone Engineering ~--'~.~ Clay Stark Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific smnples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no con'atoL Our letters and repom are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Kone Engineering Services, Ltd. 99SS Pa~e 1 of I