ST9703-LR050808Engineering 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth~ TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Ms. Suzan Taylor PO Box 9478 CoppeI1 TX 75019 Report No.: 238480 Project No.: 0510377 Date of Service: 07/28/2005 Report Date: 08/08/2005 Project: MacArthur Boulevard Widening ST 97-03 Services: Oblain samples of fi-esh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONT1L~.CTOR: JRJ Paving CONCRETE SUPPLIER: TXI PLANT: 131 SPECIFICATION REQUIREMENTS 3600 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MEASURED MIX DESIGN I.D.: 8274 SLtrM~ pLACEMENT DATE: 07/28/2005 (inches) WEATHER CONDITIONS: Partly cloudy 4.5 TIME SAMPLED: 7:15am BATCH TINIE: 6:30am TEMPERATURE (F) - AIR 72 F CONCRETE: 79 F ~mucK NO: 522 TICKET NO: 89773 AIRCONTENT(%): 4.5 UNITWEIGHT(pcO: NA OVERALL PLACEMENT LOCATION: Paving, MacArthur Boulevard, southbound side of saeet, inside lane next to median, Station 12+50 to 20+88 SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Station 12+60 CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO, TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 1 1 08/04/2005 7 6.00 28.26 115390 4080 Unbonded Cap 1 2 08/25/2005 28 0.00 0.00 Unbonded Cap 1 3 08/25/2005 28 0.00 0.00 Unbonded Cap 1 4 Hold LIMITATIONS: The test results presented herein were prepared based upon thc specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in flag without the writXen approval of Rone Engineering Services, Ltd 01SS Page 1 of 2 one Engineering 8908 Ambassador Row, DaLlas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Report No.: 238480 Ms, Suzan Taylor Project No.: 0510377 PO Box 9478 Date of Service: 07/28/2005 Coppell TX 75019 Report Date: 08/08/2005 Project: MacArthur Boulevard Widening ST 97-03 Obtain samples of fresh concrete at the placement locations, perform required field testing, ca~t compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: .[RJ Paving CONCRETE SUPPLIER: TXI PLANT: 13 1 SPECIFICATION REQUIREMENTS STRENGTH: 3600 psi ~ 28 Days SLUMP (in): 3" - 5" Am (%): 3% - 6% TEST METHOD: ASTM C- 172 ASTM C-31 ~,~ ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MEASURED MIX DESIGN I.D.: 8274 SLUMP PLACEMENT DATE: 07/28/2005 (inches) WEATHER CONDITIONS: Partly cloudy 5.0 TIME SAMPLED: 10:00am BATCHTIME: 9:081tm TEMPERATURE (F) - AIR 81 F CONCRETE: 84 F TRUCK NO: 104 TICKET NO: 89952 AIR CONTENT (%): 4.6 unIT WEIGHT (peO: NA OVERALL PLACEMENT LOCATION: Paving, MaeArthur Boulevard, southbound side of street, inside lane next to median, Station 12+50 to 20+88 SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Station 16+90 CYLINDER MAKI~D DATE AGE DIAMETER AREA SET NO. TESTED (days) (inches) (sq.in.) 2 1 08/04/2005 7 6.00 28.26 2 2 08/25/2005 28 0.00 0.00 2 3 08/25/2005 28 0.00 0.00 2 4 Hold Technician: Pat Parks Report Distribution: (1) Cii3, of Coppell (1) City of Copp¢ll Started: 6:30am MAXIMUM COMPRESSIVE LOAD STRENGTH FRACTURE (lbs. force) (psi) TYPE 116160 4110 Unbonded Cap Finished: 12:15pm Unbonded Cap Unbonded Cap Clay Stark Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc) or any other feature of similar subject manet provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shalI not be reproduced except in full without the wrinen approval of Rone Engineering Services, Ltd. 01SS Page 2 of 2 {one Engineering 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth~ TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST CLient: City of Coppell Ms. Suzan Taylor PO Box 9478 Coppell TX 75019 Repo~ No.: 238565 Project No.: 0510377 Date ofService: 07/29/2005 Report Date: 08/08/2005 Project: MacArthur Boulevard Widening ST 97-03 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: JRJ Paving CONCRETE SUPPLIER: TX][ PLANT: 151 SPECIFICATION REQUIREMENTS 3600 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 PROJECT DATA MEAS~ED MIX DESIGN I.D.: 8274 SLUMP PLACEMENT DATE: 07/29/2005 (inches) WEATHER CONDITIONS: Partly cloudy 4.5 TIWIE SAMPLED: 7:20am BATCH T~Vm: 6:33am TEMPERATURE (F) - AIR 74 F CONCRETE: 80 F TRucK NO: 826 TICKET NO: 30767 AIR CONTENT (%): 4.5 tr~rr WEIGHT (per'l: NA OVERALL PLACEMENT LOCATION: Paving, MacArthur Boulevard, south side of street, inside lane next to median. Station 20+88 to 27+20 SAMI~LE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Station 20+93 MAXIMUM COMPRESSIVE CYLINDER MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) Obs. force) (psi) TYPE 1 1 08/05/2005 7 6.00 28.26 100770 3560 Unbonded Cap 1 2 08/26/2005 28 0.00 0.00 Unbonded Cap 1 3 08/26/2005 28 0.00 0.00 Unbonded Cap 1 4 Hold LIMITATIONS: The test results presented h~rein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and report~ are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Roue Engineering Services, Ltd. 01SS Page 1 of 2 : one Engineenng 8908 Ambassador Row. Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Sta. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Report No.: 238565 Ms. Suzan Taylor Project No.: 0510377 PO Box 9478 Date of Service: 07/29/2005 Coppell TX 75019 Report Date: 08/08/2005 Project: MacArthur Boulevard Widening ST 97-03 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (ia): AIR (%): TEST METHOD: CONTRACTOR: JRJ Paving CONCRETE SUPPLIER: TX][ PLANT: 151 SPECIFICATION REQUIREMENTS 3600 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MEASURED MIX DESIGN I.D.: 8274 SLUMP PLACEMENT DATE: 07/29/2005 (inches) WEATHER CoNomONS: Partly cloudy 4.5 TIME SAMPLED: 10:40am BATCHTIME: 9:54am TEMPERATURE (F)- AIR 89 F CONCRETE: 86 F tRUCK NO: 101 TICREX NO: 91117 AIR CONTENt (%): 4.6 UNITWE, IGHT (pc0: NA OVERALL PLACEMENT LOCATION: Paving, MacArlhur Boulevard, south side of slxeet, inside lane next to median, Station 20+88 to 27+20 SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" St~ion 25+53 CYLINDER MARKED DATE AGE DIAMETER SET NO. TESTED (days) 0aches) 2 1 08/05/2005 7 6.00 2 2 08/26/2005 28 0.00 2 3 08/26/2005 28 0.00 2 4 Hold Technician: Pat Parks Report Distribution: (1) City of Coppell (l) City of Coppell Started: 6:30am MAXIMUM COMPRESSIVE AREA LOAD STRENGTH FRACTURE (sq.iu.) (Ib~ force) (psi) TYPE 28.26 99530 3520 Unbonded Cap 0.00 Unbonded Cap 0.00 Unbonded Cap Finished: 12:15pm X-~lay Stark Project Manager LBvflTATIONS: The test results presented hereto were prepared based upon the specific saraples provided for testing. We assume no responsibility for vacation in quality (composition, appearance, etc.) or may other feature of similar subject maRer provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wrinen approval of Rone Engineering Services, Ltd. 3ISS Page 2 of 2