Loading...
ST9302-LR 990823ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR CITY OF COPPELL DATE 8/23/99 COPPELL, TEXAS PROJECT SANDY LAKE ROAD OUR REPORT NO. 98881-60 PROJECT NO. ST 93-02 COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 175 8/23/99 FG-3.0 5 13.5 111.9 16.6 110 98 1-A 176 8/23199 FG-I.0 5 13.5 111.9 14.4 109 97 1-A 177 8/23/99 FG-2.0 5 13.5 111.9 13.6 109 97 1 -A TEST LOCATION: 175 21" RCP STORM SEWER LINE AT STATION #25+40 ALONG WOOD CREST 176 30" RCP STORM SEWER LINE AT STATION ~25+50 ALONG WOOD CREST 177 36" RCP STORM SEWER LINE AT STATION #25+50 ALONG WOOD CREST 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED ~ A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY wrrH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST A~L~,~ectfully S~b~ A TESTING, IN~~. Geo~ E~ · C~ Matefl~ Testing · Envfmnmentaf Enffiheed~ · Consu/finc/ ~ r T' T YF '~ I