Coppell Trade-LR050816CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0080 Service Date: July 18, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Spdngs Rd Ste 300 Addison TX 75001 ~'~1, TX 94051190 Material Information Specified Strength: 3000 psi @ 2 Batch Time: 12:47pm Supplier: TXI Truck No: 803 Ticket No: 83549 Mix I.D. No.: 9506 Water Added Onsite Before Test: 15 Gallons '1 rerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: August 16, 2005 Project: Coppell Trade Center- Bldg C NWC Sandy ~ ....  Project Number: ~rmation Sample Time: 1:30pm Date Cast: July 18, 2005 Technician: Charles A. Patterson Plant: 141 Weather Conditions: Mostly sunny Accumulative Yards: 10 Placement Method: Direct Discha~le Sample Locations: FootingsA.3/2 Placement Location: Retaining Wall Beam W of building & footings Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,O F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result Specification Test Method 4.75 3-5 ASTM C143 3.3 3-7 ASTM C231 94 ASTM C1064 90 ASTM C1064 ASTM C138 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 07/25~2005 7 94,510 3,340 1 2 6.00 28.27 08/15/2005 28 122,570 4,330 28 121,530 4,300 Average 4,320 56 The tests were performed in general accordance with applicable ASTM, AASHTO, ar DOT test methods. This report is exclusively for the use of the client indicated above and shall nut be reproduced except in full without the written consent of our company. Test resuEs transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 · CONCRETE COMPRESSIVE STRENGTH TEST Client: coppell Trade Center LP Comments (cont'd): lr rr can Project Number:94051190 Report NumbeF. 94051190.0080 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Chades A. Patterson Report Distribution: (1) Coppell Trade Center LP (1) TechniStructures (1) city of Coppell TX (1) City of Coppell TX (t) Merriman Asset Inc (1) McFadden & M;ller (1) Macatee Engineering Inc The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and ara not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2