Loading...
Coppell Trade-LR050831CONCRETE COMPRESSIVE STRENGTH TEST · Report Number: 94051190.0089 Service Date: August 2, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 'lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: August 31, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:15am Supplier: TXI Truck No: 136 Mix I.D. No.: 8206 Plant: 141 Ticket No: 93032 Sa_~_.ple Information Sample Time: 7:00am Technician: Terry Smith Weather Conditions: Accumulative Yards: 20 Placement Method: Sample Locations: 650' N of Sandy Lake Placement Location: Fire Lane, W of building Date Cast:August 2, 2005 Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 4.0 Concrete Temperature,° F: 77 Ambient Temperature, o F: 80 Plastic Unit Weight, pcf: Laboratory Test Data Set specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Specification 3-5 3-7 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 08/09/2005 7 85,120 3,010 08/0912005 7 82,700 2,920 Average 2,970 08/30/2005 28 117,460 4,150 08/30/2005 28 117,120 4,140 Average 4,'150 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report rs exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the prope~es of other apparently similar or identical Page 1 of 3 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0089 Service Date: August 2, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 '1 rerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: August 31, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 7:39am Supplier: TXI Truck No: 583 Mix I.D. No.: 8206 Plant: 141 Ticket No: 9316 Sample Information sample Time: 8:15am Technician: Terry Smith Weather Conditions: Accumulative Yards: 130 Placement Method: Sample Locations: 560' N of Sandy Lake Placement Location: Fire Lane, W of building Date Cast: August 2, 2005 Field Test Data Test Result Specification Slump, inches: 4.50 3-5 Air Content, %: 4.6 3-7 Concrete Temperature, O F: 80 Ambient Temperature, o F: 85 Plastic Unit Weight, pcf: Laboratory Test Data set specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 2 1 6.00 28.27 08/09/2005 2 2 6.00 28.27 08/09/2005 2 3 6.00 28.27 08/30/2005 2 4 6.00 28.27 08/30~2005 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 87,490 3,090 7 91,740 3,240 Average 3,170 28 120,100 4,250 28 122,410 4,330 Average 4,290 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3 0~.-~,~01-~. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0089 Service Date: August 2, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 ']rerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: August 31,2005 Project: Coppell Trade Center- Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:41am Supplier: TXI Truck No: 583 Mix I.D. No.: 8208 Plant: 141 Ticket No: 93271 Sample Information Sample Time: 9:30am Date Cast:August 2, 2005 Technician: Terry Smith Insp/Testing Weather Conditions: Accumulative Yards: 220 Placement Method: Sample Locations: 450' N of Sandy Lake Placement Location: Fire Lane, W of building Field Test Data Test Result Specification Test Method 5.00 3-5 ASTM C143 5.0 3-7 ASTM C231 81 ASTM C1064 88 ASTM C1064 ASTM C138 Slump, inches: Air Content, %: Concrete Temperature, O F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 08/09/2005 7 83,770 2,960 3 2 6.00 28.27 08/09/2005 7 86,610 3,060 Average 3,010 3 3 6.00 28.27 08/30/2005 28 118,350 4,190 3 4 6.00 28.27 08/30/2005 28 113,670 4,020 Average 4,110 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry Smith Insp/Testing Report Distribution: (1) Coppell Trade Center LP (1) Merriman Asso~ Inc (1) TechniStructures (1) McFadden & Miller (1) City of Coppell TX (1) Macatee Engineering Inc (1) City of Coppell TX Reviewed by: ~~~/ The tests were pen~ormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for t~e use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3 0~'"~-F~o