Loading...
ST9703-LR050829Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: City of Coppell Ms. Suzan Taylor PO Box 9478 Coppell TX 75019 Report No.: 238480 Project No.: 0510377 Date of Service: 07/28/2005 Report Date: 08/29/2005 MacArthur Boulevard Widening ST 97-03 Obtain samples of flesh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA MEASURED STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: JRJ Paving CONCRETE SUPPLIER: TX[ PLANT: 131 SPECIFICATION REQUIREMENTS 3600 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MIX DESIGN I.D.: 8274 SLUMP PLACEMENT DATE: 07/28/2005 (inches) WEATHER CONDITIONS: Partly cloudy 4.5 TIME SAMPLED: 7:1 Sam BATCH TIME: 6:30am TEMPERATURE (F) - AIR 72 F CONCRETE: 79 F TRUCK NO: 522 TICKET NO: 89773 AIR CONTENT (%): 4.5 UNIT WEIGHT (pcfp NA OVERALL PLACEMENT LOCATION: Paving, MacArthur Boulevard, southbound side of street, inside lane next to median, Station 12+50 to 20+88 SAMPLE LOCATION: Station I2+60 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 1 1 08/04/2005 7 6.00 28.26 115390 4080 Unbonded Cap 1 2 08/25/2005 28 6.00 28.26 152560 5400 Unbonded Cap 1 3 08/25/2005 28 6.00 28.26 146440 5180 Unbonded Cap Average 5290 1 4 Hold LIMITATIONS: The lest results presented herein were prepared based upon the specific samples provided for testing We assume no responsibility for variation in quality (composition, appearmace, etc) or any ot~er feature of similar subject maner provided by persons or conditions over which we have no control Our letrers and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without lhe wrinen approval of Rone Engineering Services, Ltd. 01SS Page I of 2 Rone Engineenng 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: City of Coppell Ms. Suzan Taylor PO Box 9478 CoppeI1 TX 75019 MacArthur Boulevard Widening ST 97-03 Report No.: 238480 Project No.: 0510377 Date of Service: 07/28/2005 Report Date: 08/29/2005 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECTDATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: JRJ Paving CONCRETE SUPPLIER: TXI PLANT: 131 SPECIFICATION REQUIREMENTS 3600 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 except 9 I 2 MEASURED MIX DESIGN LD.: 8274 SLUMP PLACEMENT DATE: 07/28/2005 (inches) WEATHER CONDITIONS: Partly cloudy 5.0 TIME SAMPLED: 10:00am BATCH TIME: 9:08am TEMPERATURE (F) - AIR 81 F CONCRETE: 84 F TRUCKNO: 104 TICKETNO: 89952 AIR CONTENT (%): 4.6 UNIT WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: Paving, MacArthur Boulevard, southbound side of street, inside lane next to median, Station 12+50 to 20+88 SAMPLE LOCATION: Station 16+90 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" C~%IN1) ER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 2 1 08/04/2005 7 6.00 28.26 2 2 08/25/2005 28 6.00 28.26 2 3 08/25/2005 28 6.00 28.26 2 4 Hold Technician: Pat Parks Report Distribution: (1) CiW of Coppell (1) City of Coppell Started: 6:30am Finished: 12:15pm 116160 4110 144360 5110 141680 5010 Average 5060 Unbonded Cap Unbonded Cap Unbonded Cap CMT Operations Manager LLMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc ) or any other feature of similar subject master provided by persons or conditions over which we have no control Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in fall without the written approval of Rone Engineering Services, Ltd 01SS Page 2 of 2