Loading...
Vista Ridge 1R-8 D-LR050913SAM ENGINEERING & TESTING, INC. li~ Serving The Goo-Industry Since 1974 '~ 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 · FAX: (972) 790-0967 CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT CLIENT: JBP, LP STANDARD 6" X 12" 5301 Village Creek Drive, Suite A / AREA 28.27 SQ. IN. PROJECT: The Plaza Infra Highway 121 & I~gemont SAMPLE DATE: 9/12/05 Lewisville & CojCpell, TX . PROJECT NO.: 308TXIK5 ATTN: Neal Heckel REPORT NO.: 26 SE&T TECHNICIAN: Mark Brumley LOCATION OF PLACEMENT: Man Hole Tops Time Arrived: 2:30 PM Concrete Supplier: LMC Time Left: 3:30 PM Ticket #: 3201020 Slump (Inches): 5 Truck #: 966 Concrete Temperature (F): 91 Time Batched: 1:59 PM % Air Content: N/A Time Sampled: 3:20 PM Total No of Test Cylinders Made: 4 Product Code: 1701 Total Cubic Yards Placed: 10 Cement: N/A Added Water: N/A Fly Ash: N/A Weather Conditions: Hot & Sunny Coarse Aggregate: N/A Air Temperature (F): 93 Water: N/A Unit Weight of Fresh Concrete: 149 % Air Content: N/A lA 7 9/19/05 4200/28 1 B 14 9/26/05 4200/28 1 C 28 10/10/05 4200/28 1 D 28 10/10/05 4200/28 Curing ASTM C-31 Test Method Cylinder Made By: Cylinders Tested By: Slump ASTM C-143 ASTM C-39 & 231 ~ SE&T Remarks: Very Truly Yours, Sadik (SAM)AI-Musawe, M.Sc., Ph,D., P.E Civil & Environmental Engineer Texas Registration Number: 61893 This report only applies to the samples tested and does not necessarily represent identical or similar samples.