Loading...
Coppell Trade-LR050906CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0111 Service Date: August 25, 2005 rEffal:l:ln 8901 Carpenter FnNy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 K~ Springs~'~ Ste 300 Addison TX 75001 Report Date: September 06, 2005 Project: Coppell Trade Center- Bldg C ~ NWC Sandy Lake/Freepo~ Coppell, TX ~ Project Number: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:22am Supplier: TXI Truck No: 922 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Result Slump, inches: 10 Air Content, %: 4.6 Concrete Temperature, o F: 104 Ambient Temperature, o F: 89 Plastic Unit Weight, pcf: N/A Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq inches) I 1 6.00 28.27 1 2 6.00 28.27 Plant: 141 Ticket No: 107032 0 Gallons 0 Gallons 1 3 1 4 Sample Information Sample Time: 7:03am Date Cast: August 25, 2005 Technician: Sergio Rodriguez Weather Conditions: Warm Accumulative Yards: 130 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: S side Paving Specification ~ ~ ~¢5"'i-M C 143 ~ 3-7 f ASTM C231 I' .,. .~' ASTM C1064 f Age at Maximum Compressive ~' Date Test Load Strength Tes~ted (days) (lbs__) (psi) ,~ 09_/01/2005 7 77,300 2,730 I.,¢W ~'~01/2005 7 75,860 2,680 ~ ~ Average 2,710 09,22,2005 28 ~ 09/22/2005 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0111 Service Date: August 25, 2005 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: September 06, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project Number: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 7:44am Supplier: TXI Truck No: 64 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Result Slump, inches: 6.00 Air Content, %: 4.6 Concrete Temperature, o F: 104 Ambient Temperature, o F: 89 Plastic Unit Weight, pcf: N/A Laboratory Test Data Set Specimen Diameter Area No. rD (inches) (sq. inches) Plant: 141 Ticket No: 1071 0 Gallons 0 Gallons Sample Information Sample Time: 8:30am Date Cast: August 25, 2005 Technician: Sergio Rodriguez Weather Conditions: Warm Accumulative Yards: 130 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Pavement, S side Specification Test Method 3-5 3-7 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 2 1 6.00 28.27 09/01/2005 7 86,530 3,060 2 2 600 28.27 09/01/2005 7 87,410 3,090 Average 3,080 2 3 09/22/2005 28 2 4 09/22/2005 28 Comments: NOTE: Truck #922 came to job site with the 21" slump, see attached sketch for placement of the concrete for this, Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Field Results Reported To: Superintendent Technician: Sergio Rodriguez Report Distribution: (1) Coppell Trade Center LP (1) TechniStructures (1) City of Coppell TX (1) City of Coppell TX (1) Merriman ASSOC Inc (1) McFadden & Miller (1) Macatee Engineering Inc The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ~'1~ OR AN GRAY IN I _ I L~ RA'I~ INLET