Loading...
Vista Ridge 1R-8 D-CS050909TREN-Tt/ CH COMP. C{ 1'0: Mike Smith Rodman Utilities FRO~VI: Ron ,less, en FAX PHONE: 972-712-0971 4_IOTAL .PAGES INCLUDING COVER Mike: Attached is a copy of tile shoring addendum for the Coppelljob. 1 will send the original in the mail Any questions -- give me a call 828 HOW¥.I.1. DRIVE 972-304-2171 COPp~-I.L ?t/XP3 75019 TR I-TECH COMP S, eptember o 2005 Rodman Utilities L.P. 1) O Box 057 · ' 75034 Fr ~co TX Re The Plaza - Coppell. Tx '(~entlemen: We understand that the existing 8 inch "stub-out" cannot be located; theref'ore, a new cormection to the existing 12 inch waterline which runs parallel to Denton Tap Road, will be required. The new 8 inch waterline is to be installed by bo~ing under the street Bore and receiving pits will be approximately 12 Feet in depth. This addendum to our original trench safety plan, covers shoring guidelines tbr lhe protection of workmen in the bore and receiving pits. Ail other requirements outlined in the original plan shall be, by reference, a part o£this document. The contractor shall usc trench shields as the primm-y means of protection with 1 inch steel plate to be installed at Ihe face and rear o£ the trench shields. If any voids occur bet:ween the l>lates/trench shields, they shall he filled with flee flowing granular material to inhibit ~y lateral movemenl of the adjacent so~s. Schematic drawings are included to show details. Respectfully, ~-" ~ '"..~ , ......... William P. Price. P.E. 'h~l~Z'~'~ DRIVE 972-30~,-21 ? 1 GOP, I~,JJ-, ~ 7501 PLAN VIEW SECTIONAL VIEW Casing BORE PI]' ITREN--TECH CO. The PI~za ~ Coppell Texas Rodn~n LJtiliti,~s L.P. I~'~ m~ I I''~ Cosing L Il RECEIVING PIT