Loading...
Vista Ridge 1R-8 D-LR050909S^M E.G .EE.I. & TEs'rl. , Serving The Goo-Industry Since 1974 ~ 1115 Luke Street, Suite 1OO Irving, Texas 75061 Phone: (972) 790-1910 · FAX: (972) 790-0967 Geotechnical Environmental CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT CLIENT: PROJECT: JBP, LP 5301 Village Creek Drive, Suite A Piano, TX 75093 _~21 &/Ridgement~ ~kewisville &~Gopp~li TX ATTN: Neal Heckel ~E&T TECHNICIAN: Brian Taylor Time Arrived: 2:00 PM Time Left: 5:00 PM 'Slump (Inches): Concrete Temperature (F): 2.75 89 Air Content: 2.2 Total No. of Test Cylinders Made: 4 Total Cubic Yards Placed: 4 Added Water: N/A Weather Conditions: Air Temperature (F): Unit Wei~ ht of Fresh Concrete: Sunny & Hot 95 146 Concrete Supplier: Ticket #: Truck #: Time Batched: Time Sampled: Product Code: Cement: Fly Ash: Coarse Aggregate: Water: % Air Content: STANDARD 6" X 12" AREA 28.27 SQ. tN. REPORT DATE: 9/9/05 SAMPLE DATE: 9/8~05 PROJECT NO.' 308TXIK5 REPORT NO.: 24 PAGE 1 OF 1 LMC 3200858 1106 3:57 PM 4:35 PM 1701 N/A N/A N/A N/A N/A lA 7 9/15/05 lB 14 ~22/05 4200/28 4200~28 1C 28 10/6/05 1 D 28 10/6/05 Curing ASTM C-31 Test Method Cylinder Made By: Slump ASTM C-143 ASTM C-39 & 231 SE&T 4200~28 4200/28 Cylinders Te~ed By: Remarks: Very Truly Yours, Sadik (SAM) AI-Musawe, M.Sc., Ph.D., P.E. Civil & Environmental Engineer Texas Registration Number: 61893 This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This report only applies to the samples tested and does not necessarily represent identical or similar samples. G:120051308txik51CpistrlCpistr241BE