Rozas Addn-LR050816 -- Concrete Compression Test Report
CMJ
7636 Pebble Drive Fort Worth, Texas 76118 Te~./(817) 284-9400 Fax: (817) 589-9993
/
Client: Td-Sta~rConstruction ~ Report Distribution: (l) Tri-Star Construction
ProJect ~"~ ~ (1) City of Coppell
CMJ Report No.: 548-5051-022
Report Date: 08/16/2005
Specifications Test Data
Strength 4000 psi @ 28 Days Placement Date 08/01/2005
Slump 3 in min 5 in max Sampled By Contractor
,Air Content 3 % min 6 % max Weather n/a
Concrete Temperature n/a Supplier/Mix Contractor Made/
Ambient Temperature n/a Air Content Method ASTM C231
Ticket Number:
Slump:
Concrete Temperature:
Placement Location:
n/a Time Batched: n/a
n/a Air Content: n/a
n/a Ambient Temperature: n/a
Stamped concrete driveway approaches
Sample Location: see above
Time Sampled: n/a
Unit Weight: n/a
Yardage (c.y.): n/a
Set # Cyl~der Test Date
Concrete Compression Test Results
Age Max Load Area
(days) (lbs. force) (sq.in.)
Strength
(psiJ
Fracture
Type
01 DRO080105.01 08/08/2005 7
01 DRO08010502 08/29/2005 28
01 DRO08010503 08/29/2005 28
01 DRO08010504 Hold
Normal cylinder size: 6" x 12"
104563 28.27 3700
Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, Ct43, Ct72, C1064, and C617 or C1231.
^^^ ALL iNFORMATION PROVIDED BY CLIENT ^^^
CMJ Engineering, Inc
R. Carl Lee, S.E.T,
CMT Manager