Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Vista Ridge 1R-8 D-LR050919
SAM ENGINEERING & TESTING, NC. I~ Serving The GeD-Industry Since 1974 ,~ 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 · FAX: (972) 790-0967 CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT CLIENT: JBP, LP ;TANDARD 6" X 12" 5301 Village Creek Drive, Suite A AREA 28.27 SQ. IN. Piano, TX 75093 PROJECT:~' , · .,, ~ "---- ~-"T~ ~11~1/ REPORT DATE: 9/19/05 ~lTgh ay lw 21 & Ridgemont SAMPLE DATE: 9/16/05 Lewisvilte & Coppell, TX PROJECT NO.: 3O8TXlK5 ATTN: Neal Heckel REPORT NO.: 29 SE&T TECHNICIAN: Brian Taylor LOCATION OF PLACEMENT: Inlet Throats- Plaza BIvd ~ Sta ~ 11+50, 6+50 & 3+80 PAGE 1 OF 1 Time Arrived: 2:30 PM Concrete Supplier: LMC Time Left: 3:30 PM Ticket g: 3201353 Slump (Inches): 4 Truck g: 1049 Concrete Temperature (F): 92 Time Batched: 1:57 PM % Air Content: 1.3 Time Sampled: 2:35 PM Total No. of Test Cylinders Made: 4 Product Code: 1851 Total Cubic Yards Placed: 10 Cement: N/A Added Water: N/A Fly Ash: N/A Weather Conditions: Warm & PaUly Cloudy Coarse A~re~ate: N/A Air Temperature (F): 90 Water: N/A Unit Weight of Fre~sh Concrete: 144 % Air Content: N/A lA 7 9/23/05 4200/28 1 B 14 9/30/05 4200/28 1 C 28 10/28/05 ~ 4200/28 1D 28 10/28/05~ ~~ B~~ j 4200~28 Cu ring ASTM C-31 Test Method Cylinders Tested By: s~p ASTU C-~43 ASTM C-39 & 23~ ~ j Remarks: ~ ~ Sadie. Sc., Ph D;~ E~ ~ Civil & Environmental Engineer Texas Registration Number: 61893 This repod only applies to the samples tested and does not necessarily represent identical or similar samples.