Loading...
Vista Ridge 1R-8 D-LR050920S^= E.G .EER .G & TESTING, INC. '~ Serving The Goo-Industry Since 1974 ,~ 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 · FAX: (972) 790-0967 Geotechn~al CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT CLIENT: PROJECT: JBP, LP 5301 Village Creek Drive, Suite A Plane, TX 75093 Lewisville & Coppell, TX ATTN: Neal Heckel SE&T TECHNICIAN: Mark Brumtey LOCATI 0 Time Arrived: 2:30 PM Time Left: 3:30 PM Slump (Inches): 4 Concrete Temperature (F): 94 % Air Content: N/A STANDARD 6" X 12" AREA 28.27 SQ. IN. ~.~EPORT DATE: 9/20/05 SAMPLE DATE: 9/19/05 PROJECT NO.: 308TXIK5 REPORT NO.: 30 Concrete Supplier: Ticket #: 7156561 PAGE 1 OF '1 LMC Truck #: 1118 Time Bitched: 2:31 PM Total No. of Test Cylinders Made: 4 1851 Total Cubic Yards Placed: 10 Cement: N/A ~.dded Water: N/A N/A Time Sampled: 3:15 PM Product Code: Fly Ash: Coarse A~l~re~late: N/A Water: N/A Sunny & Hot 97 149 % Air Content: N/A Weather Conditions: Air Temperature (F): ht of Fresh Concrete: lA 7 9/26/05 1 B 14 10/3/05 1C 28 10117/05 1D 28 10/17/05 Curing ASTM C-31 Slump ASTM C-143 Remarks: Test Method ASTM C-39 & 231 Very Truly Yours, Sadik (SAM) Al-Musawe, MSc., Ph.D., P.E. Civil & Environmental Engineer Texas Registration Number: 61893 Cylinder Made By: SE&T 4200~28 4200/28 4200/28 4200/28 By: This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This report only applies to the samples tested and does not necessarily represent identical or similar samples. G:12OO513OBtxik51CpistrlCpistr3OISF