ST9302-LR 990617ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR CITY OF COPPELL COPPELL, TEXAS DATE 6/17/99 PROJECT SANDY LAKE ROAD PROJECT NO. ST 93-02 COPPELL, TEXAS OUR REPORT NO. 98881-38 TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT' % PCF % PCF 98 6/17/99 FG-5.0 7 21.5 99.6 22.2 96 96 2-A 99 6/17/99 FG-4.0 7 21.5 99.6 24.7 95. 95 2-A 100 6/17/99 FG-3.0 7 21.5 99.6 21.5 98 98 2-A 101 6/17/99 FG-2.0 5 13.5 111.9 14.4 106 95 2-A 102 6/17/99 FG-1.0 5 13.5 111.9 17.0 109 98 2-A 103 6/17/99 FG-3.0 3 13.3 117.6 15.1 116 99 2-A 104 6/17/99 FG-2.0 5 13.5 111.9 17.5 112 100 2-A TEST LOCATION: 98 30" WATER LINE AT STATION #47 + 40 99 30" WATER LINE AT STATION //47 + 35 100 30" WATER LINE AT STATION //47+30 101 30" WATER LINE AT STATION //47+25 102 SANDY LAKE ROAD AT STATION //38+50 103 SANDY LAKE ROAD AT STATION //38 +00 104 SANDY LAKE ROAD AT STATION //37 +50 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED e A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C, PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting T '1 r 1