ST9302-LR 990514ALPHA TESTING, INC.
2209 Wisconsin St,, Suite 100
Dallas, Texas 75229-
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR
CITY OF COPPELL
COPPELL, TEXAS
DATE 5/14/99
PROJECT
SANDY LAKE ROAD
PROJECT NO. ST 93-02
COPPELL, TEXAS
OUR REPORT NO.
98881-32
TEST DATA:
TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN Pt. AGE PERCENT
NO. DATEDEPTH'~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
% pci: % PCF
77 5/14/99 FG-1.0 7 21.5 99.6 23.2 99 100 1-A
78 5/14/99 FG-2.5 7 21.5 99.6 24.1 95 95 I-A
79 5/14/99 FG-3.0 7 21.5 99.6 24.5 95 95 I-A
TEST LOCATION:
77 16" WATER LINE NORTH SIDE OF SANDY LAKE ROAD AT STATION #54+15
78 16' WATER LINE NORTH SIDE OF SANDY LAKE ROAD AT STATION #54+25
79 16" WATER LINE NORTH SIDE OF S&NDY LAKE ROAD AT STATION #54+45
1. FILL
2. NATURAL SUBGRAD~
A. IN PI.ACE PERCENT MOISTURE ANO PERCENT COMPACTION COMPLY t/VITH SPECIFICATIONS
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. UME STABILIZED
C. I~RCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
4. CEMENT TREATED D. RETEST
Geotechnical Engineedng · ~tion Materials Testing · Environmental Eng~'~edng · Consu~