Vista Ridge 1R-8 D-LR050928SAM ENe NEERING & TEST,.G,
Serving The Gao-Industry Since 1974
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 · FAX: (972) 790-0967
CONCRETE PLACEMENTINSPECTION & STRENGTH TEST REPORT
CLIENT:
PROJECT:
JBP, LP
5301 Village Creek Drive, Suite A
Piano, TX 75093
Lewisville & Coppell, TX
P, TTN: Neal Heckel
BE&T TECHNICIAN: Adel Alhemidawi
LOCATION OF PLACEMENT:
Plaza Town Sta #'s 3 + 80 & 6 + 50
STANDARD 6" X 12"
AREA 28.27 SQ. IN.
REPORT DATE: 9/28/05
SAMPLE DATE: 8/31/05
PROJECT NO.: 308TXIK$
REPORT NO.: 19
PAGE 1 OF 1
Time Arrived:
Time Left:
Slump (Inches):
Concrete Temperature (F):
% Air Content:
Total No. of Test Cylinders Made:
Total Cubic Yards Placed:
2:10 PM
4:10 PM
Concrete Supplier: LMC
Ticket #: 3200487
4 Truck #: 1026
98 Time Batched: 2:25 PM
3 3:05 PM
4
10
Added Water. N/A
Weather Conditions:
Sunny & Hot
98
Time Sampled:
Product Code: 1701
Air Temperature (F):
~f Fresh Concrete:
Cement: N/A
Fly Ash: N/A
Coarse A~lgre~late: N/A
Water: N/A
149 % Air Content: N/A
IA 7 9/7/05 149 110,000 3890
lB 14 9114105 149 4138
1C 28 9/28/05 149 127,000 4491
1 D 28 9~28~05 149 128,000
Curing ASTM C-31 Test Method
Slump ASTM C-143 ASTM C-39 & 231
Remarks: Tested concrete meete/exceeds required strength.
4527
le Shear 4200/28
4200/28
4200/28
4200/28
Cylinders Tested By:
SE&T
Ver~ Truly Yours,
Sadik (SAM)AI-Musawe, M.Sc., Ph.D., P.E.
Civil & Environmental Engineer
Texas Registration Number: 61893
This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent.
'his report onl~ applies to the samples tested and does not necessedly represent identical or similar samples.
G:12OO51308txikSICpistrlCpistrl 9/BE