Loading...
Coppell Trade-LR050923 (2)CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0111 Service Date: August 25, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 "lrerfar'on 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: September 23, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:22am Supplier: TXI Truck No: 922 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Plant: 141 Ticket No: 107032 0Gallons 0Gallons Result Slump, inches: 10 Air Content, %: 4.6 Concrete Temperature,° F: 104 Ambient Temperature, o F: 89 Plastic Unit Weight, pcf: N/A Laboratory Test Data Sa_~.~_ple Information sample Time: 7:03am Set Specimen Diameter Area No. iD (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Date Cast: August 25, 2005 Technician: Sergio Roddguez Weather Conditions: Warm Accumulative Yards: 130 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: S side Paving Specification Test Method 3-5 3-7 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 09/01/2005 7 77,300 2,730 d tests and cast compressive Comments: * Does not comply with specified strength. Services - Obtain samples of fresh concrete at the placement strength samples. 09/01/2005 7 75,860 2,68~.~,,-. Average ~ ~1~ 09/22/2005 28 96,240 ~ 09/22/2005 ~ 98,460 ~__3,4~Lr I Av age 3,440 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wriffen consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of ether apparently similar or identical materials. Page 1 of 3 0~ EML~ROI-Futara KaY CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0111 Service Date: August 25, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 '1 rerracon 8901 Carpenter Fn~,, Ste #100 Dallas, Texas 75247 (214) 63(%1010 Report Date: September 23, 2005 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 7:44am Supplier: TXI Truck No: 64 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Plant: 141 Ticket No: 1071 0Gallons 0 Gallons Result Slump, inches: 6.00 Air Content, %: 4.6 Concrete Temperature, o F: 104 Ambient Temperature, o F: 89 Plastic Unit Weight, pcf: N/A Laboratory Test Data set specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28.27 Sample Information sample Time: 8:30am Date Cast:August 25, 2005 Technician: Sergio Rodriguez Weather Conditions: Warm Accumulative Yards: 130 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Pavement, S side Specification Test Method 3-5 3-7 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 09/01/2005 7 86,530 3,060 09/01/2005 7 87,410 3,090 Average 3,080 09/08/2005 14 133,910 4,740 09/22/2005 28 147,300 5,210 Comments: NOTE: Truck #922 came to job site with a 10" slump, see attached sketch for placement of the concrete for this. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical Page 2 of 3 CONCRETE COMPRESSIVE STRENGTH TEST Client: Coppell Trade Center LP '1 rermcon Project Number:94051190 Report Number: 94051190.0111 Comments (cont'd): Field Results Reported To: Superintendent Technician: Sergio Rodriguez Report Distribution: (1) Coppell Trade Center LP (1) TechniStructures (1) City of Coppell TX (1) City of Coppell TX (1) Merriman Assoc Inc (1) McFadden & Miller (1) Macatee Engineering The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. 9.50' OR AN ORAY EQUAL)'-- L RATE INLET