Loading...
ST9302-LR 990401ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/62G8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: PROJECT: CITY OF COPPELL COPPELL, TEXAS SANDY LAKE ROAD PROJECT I~i ST 93-02 ~)UR COPPELL, TEXAS DATE OF ISSUE: 04/01/99 REPORT NO.: 98881-22 LOCATION OF CONCRETE PLACEMENT FIELD DATA SANDY LAKE CHANNEL, STATION 9+25, SOUTH SIDE DATE ~L~CE~ D4/01/99 TIME / ~4:15 · LIJMP (ASTM C-t43) AIRCONTENT (AST~ C-,~ [] ORC-I/~ I~ 4.25 NR TEMKR~llJ~ 69 CONCRETE TEMPERATURE 78 ~AI~ ~ 04/02/99 29 Dr=LNF. R ~ NO. 220946 M~X m~3m~R'nONS (SS~ CEMF.~T N/A WATER N/A FINE Aee~Ee~TE N/A FIELD DATA Wll lcd BY D.H. MIX DATA SUBMITTED BY PIONEER SPECIMENs CAPPED IN AcCoRDANCE wl'rH ASTM C417 [] OR C-t25t. E] ~ ~TE N/A ~UA COMPRESSION TEST RESULTS (ASTM LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE NO. CURING TESTED DAYS LOAD STRENGTH, PSI 21 LAB 04/08/99 7 104,372 28.27 3,690 22 LAB 04/29199 28 165,509 28.27 5,850 23 LAB 04/29/99 28 155,837 28.27 5,510 24 LAB HOLD H 28.27 ssxcmcat~s 28 3 ,O00 [] comjxu~m test resu~ do nc~ c~npey [] REMARKS: ~ TESTING, IRC. Geotechn/co/Enffiheer/ng · ~ Motedo/s TestY~ · Envkc~r~/c~~ · ~ ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR CITY OF COPPELL COPPELL, TEXAS DATE 4/1/99 PROJECT SANDY LAKE ROAD PROJECT NO. ST 93-02 COPPELL, TEXAS OUR REPORT NO. 98881-21 TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENTt % PCF % PCF 46 4/1/99 FG-1.5 5 13.5 111.9 13.6 107 96 1-A 47 4/1/99 FG-3.0 5 13.5 111.9 15.2 108 96 1 -A 48 4/1/99 FG-5.0 5 13.5 111.9 13.5 110 98 1 -A TEST LOCATION: 46 30" WATER LINE AT STATION #21 +05 47 30" WATER LINE AT STATION #21 +20 48 30" WATER LINE AT STATION//21 +35 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4.CEMENT TREATED A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B, PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST