Loading...
ST9302-LR 990323ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: PROJECT: CITY OF COPPELL COPPELL, TEXAS SANDY LAKE ROAD PROJECT NO. ST 9302 COPPELL, TEXAS DATE OF ISSUE: OUR REPORT NO.:( 03/23/99 98881-20 LOCATION OF CONCRETE PLACEMENT FIELD DATA SANDY LAKE ROAD DRAINAGE CHANNEL, STATION 2+25, LEFT CHANNEL WALL DATE PLACED 03~23~99 TIME ~15:20 SLUMP (ASTM C-143) J 2.75 AIR CONTENT (ASTM C-231 [] OR C-173 [~ 5.25 AIR TEMPERATURE 60 CONCRETE TEMPERATIJRE 71 DATE RECEIVED 03124199 FIELD DATA SUBMITTED BY I.R. ./- MIX DATA SuBMrn'ED BY NIA SPECIMENS cAPPED IN ACCORDANCE WITH ASTM C-617 [] OR C-123t COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE Ii' X 12") PLANT 22 DEUVER TICKET NO. 219501 MIX PROPORTIONS CEMENT NIA WATER N/A FINE AGGREGATE N~A C(X~SE ~',e~-,ATE NIA ADMIXTURE N/A (ASTM C-39) LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE NO. CURING TESTED DAYS LOAD STRENGTH, PSI 17 LAB 03/30/99 7 104,090 28.27 3,680 18 LAB 04120199 28 160,146 28.27 5,660 19 LAB 04/20/99 28 173,879 28.27 6,150 20 LAB HOLD H 28.27 specmcauo.~ 28 3,000 REMARKS: LOCATION PROVIDED BY SITE INSPECTOR representative. I"'1 Cylinders made by Amhitect's ers picked up by ALPHA [] Cyfinders delivered to ALPHA ~ testat°fYlesults comply with applicable specif'~dions. [] Compression test results do nol comply with applicable specifications. Geotechnical Englneeflng · Construction Mafedals Testing · Environmental Engineering · ~lting ;' 1[ ~'[' 'IT I TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: CITY OF COPPELL COPPELL, TEXAS DATE OF ISSUE: 03/23/99 PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93-02 OUR REPORT NO.: COPPELL, TEXAS 98881-20 LOCATION OF CONCRETE PLACEMENT FIELD DATA SANDY LAKE ROAD DRAINAGE CHANNEL, STAT1ON 2+25, LEFT CHANNEL WALL DATE PLACED 03/23/99 TIME j 15:20 SLUMP (ASTM C-143) / 2.75 AIR CONTENT (ASTM C-231 I-I OR C-173 [~ 5.25 AIR TEMPERATURE 60 CONCRETE TEMPERATURE 71 DATE RECEIVED 03/24/99 FIELD DATA SUBMITTED BY [.R. MIX DATA SUBMITTED BY SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 -1231 [] PLANT 22 DELIVER TICKET NO. 219501 MIX PROPORTIONS (SSD) CEMENT N/A WATER N/A FINE AGGREGATE N/A COARSE AGGREGATE N/A ADMIXTURE N/A COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12") (ASTM C~lS) LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE NO. CURING TESTED DAYS LOAD STRENGTH, PSI 17 LAB 03/30/99 7 104,090 28.27 3,680 18 LAB 04/20/99 28 28.27 19 LAB 04/20/99 28 28.27 20 LAB HOLD H 28.27 Specifications 28 3,000 REMARKS: LOCATION PROVIDED BY SITE INSPECTOR J~inders made by ALPHA representative. [] Cylinders made by Architect's o~ Contractor's representative. ers picked up by ALPHA laboratoqf. [] Cylinders delivered to ALPHA laboratory. [] Compression lest results comply with applicable specifications, [] Compression test results do not comply with applicable specit'mations. )Respectfully Submitted Geotechnlcal E~ · Construction Materials Testing · Envkonmental Engineering · Consutflng ~ ~ 1' l' r 'T I