Loading...
ST9302-LR 990119ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR CITY OF COPPELL COPPELL, TEXAS DATE 1/19/99 PROJECT SANDY LAKE ROAD PROJECT NO. ST 93-02 COPPELL, TEXAS , OUR REPORT NO. 98881-13 TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM lAB IN PtAC~ IN P,.ACE ~ NO. DATEDEPTH~ NUMBER M(~S~J~E O~Y ~ M~STURE DRY ~ COMPACTION COMMENT · % pc{= % PCF 35 1/19/99 FG-3.0 3 13.3 117.6 16.3 113 96 I-A 36 1/19/99 FG-2.0 3 13.3 117.6 13.4 113 96 I-A 37 1 I19/99 FG-1.0 3 13.3 117.6 15.4 113 96 1 -A I C~.TM I LUb/'~ I IUIII. 35 48' STORM SEWER R.C.P. AT STATION #79+60 36 48' STORM SILVER R.C.P. AT STATION #79+80 37 48· STORM SEWER R.C.P. AT STATION tt,80+00 1. FILL 2. NATURAL 3. LIME STAeJUZED # A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACIlON COMPLY WITH SPECU:ICATIO~8 B. PERCE]dT COMPACTION DOE8 NOT COMPt. Y WITH SPECIFICATIOf~ C. PERCENT IN PtA, CE MOISTURE DOES NOT COMPLY WITH SPECIFICATIOn6 4. CEMENT TREATED D. RETEST Geo~E~ · ~ Moferk~ Tes#ng · ~~ · ~