Vista Ridge 1R-8 D-LR051005SAM ENGINEERING & TESTING, INC.
Serving The Goo-Industry Since 1974 '~
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 · FAX: (972) 790-0967
CLIENT:
CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT
JBP, LP STANDARD 6" X 12"
5301 Village Creek Drive, Suite A AREA 28.27 SQ. IN.
Plane, TX 75093
PROJECT: fThe Pl~a_.~,J~ucture
~.,I,~121 & Ridgemont
Lewisville & Coppell, TX
~.TTN: Neal Heckel
SE&T TECHNICIAN: Brian Taylor
REPORT DATE: 10/5/05
SAMPLE DATE: 9/6/05
PROJECT NO.: 308TXlK5
REPORT NO.: 23
LOCATION OF PLACEMENT: Box Culvert Westbound 121
PAGE 1 OF 1
Time Arrived: 2:00 PM Concrete Supplier: LMC
Time Left: 3:00 PM Ticket #: 3200707
3.25 Truck #: 964
Concrete Temperature (F): 86 Time Batched: 1:55 PM
% Air Content: 1.9 Time Sampled: 2:30 PM
Total No. of Test Cylinders Made: 4
Total Cubic Yards Placed: 10
Added Water: N/A
Weather Conditions:
Air Temperature (F):
Sunny & Hot
96
145
Product Code: 1701
Cement: N/A
Fly Ash: N/A
Coarse A~lregate: N/A
Water: N/A
% Air Content:
1A 7 9/13/05 145 94,000 3324
lB 14 9/20/05 146 134,000 4739
lC 28 10/4/05 145 136,000 4810
1D 28 10/4/05 146 137,000 4845
Curing ASTM C-31 Test Method Cylinder Made By:
Slump ASTM C-143 ASTM C-39 & 231 SE&T
Remarks: Tested concrete meeta/exceeds required strength.
N/A
Single Shear
Sin~lle Shear
Single Shear
Single Shear
4200/28
4200/28
4200/28
4200/28
Cylinders Tested By:
~6E&T
Very Truly Yours,
Sadik (SAM)AI-Musawe, MSc., Ph.D., P.E.
Civil & Environmental Engineer
Texas Registration Number: 61893
This report is for the sole use of the client addressed. The use of our company name must receive our prior wdtten consent.
This report only applies to the samples tested and does not necessarily represent identical or similar samples.
G:120051308txik51CpistrlCpistr231OE