Vista Ridge 1R-8 D-LR051006SAM ENGINEERING & TESTING, L.P.
Serving The Geo-lndustry Since 1974
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 · FAX: (972) 790-0967
CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT
CLIENT: JBP, LP STANDARD 6" X 12"
AREA 28.27 SQ. IN.
)ROJECT:
5301 Village Creek Ddve, Suite A
Piano, TX 75093
Lewisville & Coppell, TX
,TI'N: Neal Heckel
E&T TECHNICIAN: Brian Taylor
PLACEMENT: Box Culvert
REPORT DATE: 10/6/05
SAMPLE DATE: 9/8105
PROJECT NO.: 308TXIK5
REPORT NO.: 24
1 OF1
2:00 PM
Time Left: 5:00 PM
Slump (Inches): 2.75
Con~:~e~e Tei~pe,-ature (FI: 89
% Air Cu.[=.~: 2.2
Total No. of Test C¥1indera Made: 4
Total Cubic Yards P!~_c_~'l: 4
Added Water. N/A
Weather
Sunny & Hot
95
146
Concrete SUpplier: LMC
Ticket #: 3200858
Truck #: 1106
3:57 PM
Time
'ime Sa~p;ed: 4:35 PM
Product Code: 1701
ement: N/A
FI*/Ash: NIA
Coarse Augregate: N/A
Water: N/A
) Air Co.k;.[: NIA
150
Curing ASTM C-31 Test Method Cylinder Made
Slump ASTM C-143 ASTM C-39 & 231 SE&T.~-,.~ SE&T
Very Tr: Yours,
Civil & Environmental Engineer
Texas Registration Number: 61893
iThis report is for the sole use of the client addressed. The use of our company name must receive our prior written consent.
iThis report only applies to the samples tested and does not necessarily represent identical or similar samples.
G:/2005/308txik5/Cpistr/Cpistr24/B E