Loading...
Vista Ridge 1R-8 D-LR051007 & TESTING, L.P. ~ Serving The Geo-lndustry Since 1974 ~ 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 · FAX: (972) 790-0967 CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT CLIENT: JBP, LP STANDARD 6" X 12" AREA 28.27 SQ. IN. PROJECT: 5301 Village Creek Drive, Suite A Piano, TX 75093 ~--~Pl~a Infrastructure ~ -- I-I1~,..~_1.11~" ° P.;~,,,U,,L Lewisville & Coppell, TX ATTN: Neal Heckel SE&T TECHNICIAN: Brian Taylor LOCATION OF PLACEMENT: Time Arrived: 2:00 PM Slump (Inches): Concrete Temperature (F): % Air Content: REPORT DATE: 10/7/05 AMPLE DATE: 9/9/05 ROJECT NO.: 308TXIK$ REPORT NO.: 25 - Villa Lane PAGE 1 OF 2 Concrete Supplier: TXI Ticket #: Time Left: 5:00 PM C698079 4.5 Truck #: 831 90 Time Batched: 12:45 PM 1.2 Time Sampled: 2:10 PM Total No. of Test Cylinders Made: 4 Total Cubic Yards Placed: 8 ~,dded. Water: 10 Gallons Weather Conditions: Hot & Sunny 95 Product Code: B8274 Cement: N/A ~ Ash: N/A Coarse Aggregate: N/A Water: N/A 145 % Air Content: N/A Air Temperature (F): ht of Fresh Concrete: 1A 7 9/16/05 146 98,000 3466 le Shear 4000/28 1 B 14 9/23/05 145 115,000 4067 ~ Shear 4000/28 1C 28 10/7/05 145 140,000 4951 le Shear 1D 28 10/7/05 144 142,000 5022 4000/28 Curing ASTM C-31 Test Method Cylind Cylinders Tested By: Slump ASTM C-143 ASTM C-39 & 231 SE&T SE&T Remarks: Tested concrete meets/exceeds required strength. Very Truly Yours, Sadik (SAM) AI-Musawe, M.Sc., Ph.D., P.E. Civil & Environmental Engineer Texas Registration Number: 61893 This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This report only applies to the samples tested and does not necessarily represent identical or similar samples. SAM ENG NEERIN( &TEST, NG, L.P. Serving The Goo-Industry Since 1974 ,~ 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 · FAX: (972) 790-0967 CLIENT: PROJECT: CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT JBP, LP 5301 Village Creek Drive, Suite A Piano, TX 75093 The Plaza Infrastructure Highway 121 & Ridgemont Lewisville & Coppell, TX ~,TTN: Neal Heckel SE&T TECHNICIAN: Brian Taylor LOCATION OF PLACEMENT: STANDARD 6" X 12" AREA 28.27 SQ. IN. REPORT DATE: 10/7/05 SAMPLE DATE: 9/9/05 PROJECT NO.: 308TXIK5 REPORT NO.: 25 ) of Man Hole h Westbound 121 PAGE 2 OF 2 Time Arrived: 2:00 PM Concrete Supplier: LMC Time Left: 5:00 PM Ticket #: 7156323 3.75 Truck #: 1125 Concrete Temperature (F): 89 Time Bitched: 3:05 PM % Air Content: 1.6 Total No. of Test Cylinders Made: 8 Total Cubic Yards Placed: 6 3:40 PM Product Code: 1701 Cement: N/A Added Water: 0 ~ Ash: N/A Hot & Sunny N/A 98 Water: N/A 146 % Air Content: N/A Weather Conditions: 2A 7 2B 14 2C 28 2D 28 Curing ASTM C-31 Slump ASTM C-143 Remarks: 9/16/05 9/23/05 10/7/05 10/7/05 145 99,OOO 145 111,000 145 139,000 144 140,000 Test Method ASTM C-39 & 231 Tested concrete meets/exceeds required strength. 3501 3925 4916 4951 CylinderMade By: SE&T Single Shear Sin~lle Shear Sin~lle Shear Single Shear 4200/28 4200/28 4200/28 4200/28 Cylinders Tested By: SE&T Very Truly Yours, Sadik (SAM) AI-Musawe, MSc., Ph.D., P.E. Civil & Environmental Engineer Texas Registration Number: 61893 This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This report only applies to the samples tested and does not necessarily represent identical or similar samples.