Loading...
ST9302-LR001228 (3)ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Teatad For: Fax Number: CITY OF COPPELL ATTN: KEN GRIFFIN 255 PARKWAY BLVD. COPPELL, TX 75019 (972) 304-3570 Project De,c: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS Our Report No.: 98881-174 I#ua Date: 12/28/2000 FIELD DA TA Placement Location: PAVING, STATION 75+00 APPROACH SANDY LAKE & MOCKINGBIRD Data Placed: 11/30/00 Slump (AS'TM C-143): 2.5 Air Content: 4.75 (ASTM C-173) Air Temperature: 68 Specimen Temperature: 70 Delivery Method: PICKED UP BY ALPHA Field Data ~JblTiltted By: HENSHAW, EKENG A MIx Data SubmiRed By: ED BELL Plant Number: -5.5 SK Delivery Tl~'ket No.: N/A Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: T~pe: $~'__: Te~*__~_: (Dave): Length Width _n!.___.me~ ~1. In. Load: PSI: 223 LAB C-1231 12/5/00 5 12 N/A 6 28.27 68789 2430 224 LAB C-1231 12/7/00 7 12 N/A 6 28.27 85498 3020 225 LAB 12/28/00 28 12 N/A 6 28.27 110112 3890 226 LAB HOLD HOLD 12 N/A 6 28.27 0 ~.lfi_,~_H_h_ ns: 28 3000 Relulte to Date: PASS