ST9302-LR001228 (5)
ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Teeted For: CiTY OF COPPELL ATTN: KEN GRIFFIN 255 PARKWAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project De,c: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS Our Report No.: 98881-176 I~ue Date: 12/28/2000 FIELD DATA Placement Location: Dete Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Delivery Method: FIMd Data Submitted By: Mix Data Submitted By: PAVING, SANDY LAKE RD. O STATION 84+50 (EASTBOUND) 11/29/00 1:30 PM 3 5.5 (ASTM C-173) 81 11/30/00 PICKED UP BY ALPHA SANDERS, JUSTIN S. BELL CONST. Plant Number: ON SITE-6.0 SK Delivery Ticket No.: N/A Made By: ALPHA Cored Specificetlon: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Core Cap Date Age Avg. Avg. Avg Deplh/ Area: Max NQ.: Type: ~%"2~: Te~__t,~l_-__ (DayI): Length Width Diameter 8(]. In. Load: PSI: 232 LAB C-1231 12/6/00 7 12 N/A 6 28.27 108672 3840 233 LAB 12/27/00 28 12 N/A .6 28.27 133579 4720 234 LAB 12/27/00 28 12 N/A 6 28.27 134447 4750 235 LAB HOLD HOLD 12 N/A 6 28.27 0 SpeclflCatlonl: 28 -i Re~ult~ to Date: