ST9302-LR001207ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: CITY OF COPPELL ATTN: KEN GRIFFIN 255 PARKWAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project Desc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS Our Report No.: 98881-172 lesue Date: 12/07/2000 FIELD DA TA Placement Location: Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Delivery Method: Field Data Submitted By: Mix Data Submitted By:. PAVING, STATION 74+54 ON SANDY LAKE RD. 11/30/0O 9:00 AM 2 5.25 (ASTM C-173) 65 70 12/1/00 PICKED UP BY ALPHA HENSHAW, EKENG A ED BELL Plant Number: -5.5 SK Delivery Ticket No.: N/A Mede By:. ALPHA Cured Speciflcetlon: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Da~}: Len~lth Wlah _n!__.m~er Sq. In. Lo-_d: PSI: 215 LAB 12/4/00 4 12 N/A 6 28.27 77841 2750 216 LAB C-1231 12/7/00 7 12 N/A 6 28.27 80494 2840 217 LAB 12/28/00 28 12 N/A 6 28.27 0 218 LAB HOLD HOLD 12 N/A 6 28.27 0 Specificetion$: 28 ~ Results to Date: N/A Notes: