Loading...
ST9302-LR001207 (2)ALPHA TESTING, INC. 2209 Wisconsin St., Suite 10 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: CITY OF COPPELL ATTN: KEN GRIFFIN 255 PARKWAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project Desc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS Our Report No.: 98881-173 Issue Date: 12/0712000 FIELD DA TA Placement Location: Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: PAVING, STATION 68+50 ON SANDY LAKE RD. 11/30/00 12:30 PM 2.5 5.75 (ASTM C-173) 67 Specimen Temperature: 70 Date Recalved: 12/1/00 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: HENSHAW, EKENG A Mix Data Submitted By:. ED BELL Plant Number: -5.5 SK Delivery Ticket No.: N/A Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: T~/pe: Spec: Tested: (Da~/s): Length Width Diameter Sq. In. Load: PSh 219 LAB C-1231 12/5/00 5 12 N/A 6 28.27 71548 2530 220 LAB C-1231 12/7/00 7 12 N/A 6 28.27 91047 3220 221 LAB 12/28/00 28 12 N/A 6 28.27 0 222 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: N/A Notes: Respectfully Submitted By: