ST9302-LR001207 (3)ALPHA TESTING, INC. 2209 Wisconsin St., Suite 10 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Teated For: CITY OF COPPELL ATTN: KEN GRIFFIN 255 PARKWAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project Deac: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS Our Report No.: 98881-174 Issue Date: 12/0712000 FIELD DA TA Placement Location: Data Placed: TIma Placed: Slump (ASTM C-143): Air Content: Air Temperature: Spaclmen Temperature: Date Received: Delivery Method: Field Data Submitted By:. Mix Data Submitted By: PAVING, STATION 75+00 APPROACH SANDY LAKE & MOCKINGBIRD 11/30/00 2:45 AM 2.5 4.75 (ASTM C-173) 68 70 12/1/00 PICKED UP BY ALPHA HENSHAW, EKENG A ED BELL Plant Number: -5.5 SK Delivery Ticket No.: N/A Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Data Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tssted: (Da~s): Length Width Diameter S~. In. Load: PSI: 223 LAB C- 1231 12/5/00 5 12 N/A 6 28.27 68789 2430 224 LAB C-1231 12/7/00 7 12 NIA 6 28.27 85498 3020 225 LAB 12/28/00 28 12 NIA 6 28.27 0 226 LAB HOLD HOLD 12 N/A 6 28.27 0 Specificationa: 28 3000 Results to Date: N/A Notes: