Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ST9302-LR001207 (5)
ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Tested For: Fax Number: CITY OF COPPELL ATrN: KEN GRIFFIN 255 PARKWAY BLVD. COPPELL, TX 75019 (972) 304-3570 Project Dssc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS Concrete Compression Test Report Our Report No.: 98881-176 Issue Date: 12/0712000 FIELD DA TA Placement Location: Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Delivery Method: Field Data Submitted By: Mix Data Submitted By: PAVING, SANDY LAKE RD. ~ STATION 84+50 (EASTBOUND) 11/29/00 1:30 PM 3 5.5 (ASTM C-173) 65 81 11/30/00 PICKED UP BY ALPHA SANDERS, JUSTIN S. BELL CONST. Plant Number: ON SITE-6.0 SK Delivery Ticket No.: N/A Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cum Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 232 LAB C-1231 12/6/00 7 12 N/A 6 28.27 108672 3840 233 LAB 12/27100 28 12 N/A 6 28.27 0 234 LAB 12/27/00 28 12 N/A 6 28.27 0 235 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: N/A Notes: