ST9302-LR001205 (2)ALPHA TESTING, INC. 2209 Wisconsin St., Suite 10 Dallas, Texas 75229 (972) §20-8911 Concrete Compression Test Report Teated For: CITY OF COPPELL ATi'N: KEN GRIFFIN 255 PARKWAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project Desc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS Our Report No.: 98881-173 Issue Date: 12/05/2000 FIELD DA TA Placement Location: Date Placed: Time Placed: Slump (ASTM 0-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Delivery Method: Field Date Submitted By: Mix Date Submitted By:. PAVING, STATION 68+50 ON SANDY LAKE RD. 11/30/00 12:30 PM 2.5 5.75 (ASTM C-173) 67 7O 12/1/00 PICKED UP BY ALPHA HENSHAW, EKENG A ED BELL Plant Number: -5.5 SK Delivery Ticket No.: N/A Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Teated: (Da~s): Length Width Diameter Sq. In. Load: PSI: 219 LAB C-1231 12/5/00 5 12 N/A 6 28.27 71548 2530 220 LAB 12/7100 7 12 N/A 6 28.27 0 221 LAB 12/28/00 28 12 NIA 6 28.27 0 222 LAB HOLD HOLD 12 NIA 6 28.27 0 Specifications: 28 3000 Notes: Results to Date: N/A